0x1010
Disk SMART Event: The logged
device generated a PFA condition
0x1012
Destination Driver Unrecovered
Error: Logged when the destination
driver has an unrecovered error from
the drive.
0x1013
Destination Diagnostic Failure:
Logged when destination driver level 0
diagnostics failed for the specified
channel
0x1014
Reassign Block Due to Write
Failure: Logged when the destination
driver issues a reassign block to the
drive due to a write failure.
0x1015
Bad Mode Select Parameters:
Logged when the controller has
detected a drive with Mode Select
parameters that are not recommended
or which could not be changed.
390
Informational
Error (0x1)
(0x0)
Informational
Error (0x1)
(0x0)
Informational
Error (0x1)
(0x0)
Informational
Error (0x1)
(0x0)
Informational
Error (0x1)
(0x0)
Drive (0x1)
Controller
(0x8)
Controller
(0x8)
Controller
(0x8)
Controller
(0x8)