0x2247
Unrecovered Interrupted Write:
Logged when a LUN is marked DEAD
due to a media error failure during
SOD. An error occurred during
Interrupted Write processing causing
the LUN to transition to the DEAD
State. SK/ASC/ASCQ =
0x06/0x3F/0xEB will be offloaded for
this error.
0x2248
Unrecovered Write Failure: Logged
when the configuration manager
posts and UA/AEN of ASC/ASCQ =
0x3F/0x80 indicating the controller set
the drive state to "Failed – Write
Failure".
0x2249
Disk Too Small: Logged when the
configuration manager posts and
UA/AEN of ASC/ASCQ = 0x3F/0x8B
indicating the controller set the drive
state to "Drive Capacity < Minimum".
0x224A
Wrong Sector Size: Logged when
the configuration manager posts and
UA/AEN of ASC/ASCQ = 0x3F/0x8C
indicating the controller set the drive
state to "Drive has wrong blocksize".
0x224B
Disk Format Failed: Logged when
the configuration manager posts and
UA/AEN of ASC/ASCQ = 0x3F/0x86
indicating the controller set the drive
state to "Failed – Format failure".
0x224C
Wrong Disk Removed / Replaced:
Logged when the configuration
manager posts and UA/AEN of
ASC/ASCQ = 0x3F/0x89 indicating
the controller set the drive state to
"Wrong drive removed/replaced".
Critical (0x1)
Notification
(0x4)
Critical
Failure
(0x1)
(0x2)
Critical
Notification
(0x1)
(0x4)
Critical
Notification
(0x1)
(0x4)
Critical
Notification
(0x1)
(0x4)
Informational
Notification
(0x0)
(0x4)
Volume (0xD)
Drive (0x1)
Drive (0x1)
Drive (0x1)
Drive (0x1)
Drive (0x1)