Information and Error Messages
Table 9: Product Manager Messages (Continued)
Cannot retrieve port
statistics.
Cannot retrieve switch
date and time.
Cannot retrieve switch
state.
Cannot run diagnostics
on a port that is failed.
Cannot run diagnostics
on an active E-port.
Cannot run diagnostics
on a port that is not
installed.
210
Message
Port statistics cannot be
retrieved by the
Product Manager
application because
the Ethernet link is
down or busy.
The director or switch
date and time cannot
be retrieved by the
Product Manager
application because
the Ethernet link is
down or busy.
The director or switch
state cannot be
retrieved by the
Product Manager
application because
the Ethernet link is
down or busy.
Port diagnostics
(loopback tests) cannot
be performed on a
port that has failed any
previous diagnostic
(power-on diagnostic,
online diagnostic, or
loopback test). The
amber LED associated
with the port
illuminates to indicate
the failed state.
Port diagnostics cannot
be performed on an
active E-port.
Port diagnostics cannot
be performed on a
port card that is not
installed.
Description
Retry the operation later. If the
condition persists, contact the
next level of support.
Retry the operation later. If the
condition persists, contact the
next level of support.
Retry the operation later. If the
condition persists, contact the
next level of support.
Reset the port and perform
diagnostics again.
Run diagnostics on an E-port
only when it is not active.
Run diagnostics only on a port
that is installed.