To create PPTP users, you should consult the
possible to use the MikroTik router as a RADIUS client to register the PPTP users, see the
how to do it.
Property Description
authentication ( multiple choice: pap | chap | mschap1 | mschap2 ; default: mschap2 ) -
authentication algorithm
default-profile - default profile to use
enabled ( yes | no ; default: no ) - defines whether PPTP server is enabled or not
keepalive-timeout ( time ; default: 30 ) - defines the time period (in seconds) after which the router
is starting to send keepalive packets every second. If no traffic and no keepalive responses has came
for that period of time (i.e. 2 * keepalive-timeout), not responding client is proclaimed disconnected
mru ( integer ; default: 1460 ) - Maximum Receive Unit. The optimal value is the MRU of the
interface the tunnel is working over decreased by 40 (so, for 1500-byte ethernet link, set the MRU
to 1460 to avoid fragmentation of packets)
mtu ( integer ; default: 1460 ) - Maximum Transmission Unit. The optimal value is the MTU of the
interface the tunnel is working over decreased by 40 (so, for 1500-byte ethernet link, set the MTU
to 1460 to avoid fragmentation of packets)
Example
To enable PPTP server:
[admin@MikroTik] interface pptp-server server> set enabled=yes
[admin@MikroTik] interface pptp-server server> print
enabled: yes
authentication: mschap2,mschap1
keepalive-timeout: 30
default-profile: default
[admin@MikroTik] interface pptp-server server>

PPTP Users

Description
The PPTP users are authenticated through a RADIUS server (if configured), and if RADIUS fails,
then the local PPP user databese is used. See the respective manual sections for more information:
RADIUS client
PPP User AAA

PPTP Server User Interfaces

Home menu level: /interface pptp-server
Description
Page 348 of 695
Copyright 1999-2007, MikroTik. All rights reserved. Mikrotik, RouterOS and RouterBOARD are trademarks of Mikrotikls SIA.
Other trademarks and registred trademarks mentioned herein are properties of their respective owners.
mtu: 1460
mru: 1460
PPP secret
and