[admin@MikroTik] interface farsync>
You can monitor the status of the synchronous interface:
[admin@MikroTik] interface farsync> monitor 0
card-type: T2P FarSync T-Series
state: running
firmware-id: 2
firmware-version: 0.7.0
physical-media: V35
cable: detected
clock: not-detected
input-signals: CTS
output-signals: RTS DTR
[admin@MikroTik] interface farsync>

Troubleshooting

Description
The farsync interface does not show up under the interface list
Obtain the required license for synchronous feature
The synchronous link does not work
Check the cabling and the line between the modems. Read the modem manual

Synchronous Link Applications

MikroTik router to MikroTik router
Let us consider the following network setup with two MikroTik routers connected to a leased line