[Sense:]Strain:bridge:[Type]; [Sense:]Strain:connect; [Sense:]Strain:bridge[:Type]? (@<Channel>); [Sense:]Strain:connect <Select>,(@<Ch_List>) - VXI VT1422A User Manual

Remote channel multi-function dac module user’s and scpi programming manual
Table of Contents

Advertisement

Usage

[SENSe:]STRain:BRIDge:[TYPE]?

Parameters
Comments
Usage

[SENSe:]STRain:CONNect

Parameters
Comments
Chapter 7
Send with VXIplug&play Function: hpe1422_cmd(...)
SENS:STRAIN:BRID Q120,(@10000:10031)
[SENSe:]STRain:BRIDge[:TYPE]? (@<channel>)
bridge configuration for channel specified by <ch_list>.
Parameter
Parameter
Name
Type
channel
channel list (string)
The <channel> parameter must be a single channel only.
Returned Value: one of "FBEN" | "HBEN" | "Q120" | "Q350" | "USER".
The data type is string.
Related Commands: SENSE:STR:BRID[:TYPE]
*RST Condition: SENS:STR:BRID:TYPE FBEN for all VT1529A/B channels
Send with VXIplug&play Function: hpe1422_cmdString_Q(...)
SENS:STRAIN:BRID (@10022)
[SENSe:]STRain:CONNect <select>,(@<ch_list>)
channels specified by <ch_list> to sense either the strain bridge output or the bridge
excitation supply. Only one channel for each VT1529A/B needs to be specified in
<ch_list> and all channels on that unit will configure as specified in <select>.
Parameter
Parameter
Name
Type
select
discrete (string)
ch_list
channel list (string)
Related Commands: SENSE:STRAIN:..., SENSE:FUNC:STRAIN...
*RST Condition: SENS:STR:CONN BRIDGE for all VT1529A/B channels.
configure strain RSC unit channels 00-31
connected to on-board channel 00 to 120
ohm quarter bridge
returns the VT1529A/B's
Range of
Values
10000 - 15731
check strain RSC unit channel 22 bridge
configuration connected to on-board
channel 00
connects the VT1529A/B
Range of
Values
BRIDge | EXCitation
10000 - 15731
VT1422A Command Reference
[SENSe]
Default
Units
none
Default
Units
none
none
363

Advertisement

Table of Contents
loading

Table of Contents