Field Wiring Of The Vt1586A - VXI VT1422A User Manual

Remote channel multi-function dac module user’s and scpi programming manual
Table of Contents

Advertisement

Field Wiring of the
VT1586A
Ch0
Ch1
Ch2
Sense +
Sense +
Sense +
Ch0
Ch1
Ch2
Sense -
Sense -
Sense -
Ch0
Ch0
Ch2
Excitation -
Excitation +
Ex.Sense +
Ch4
Ch4
Ch6
Ex.Sense +
Ex.Sense -
Ex.Sense +
Ch4
Ch5
Ch6
Sense -
Sense -
Sense -
Ch4
Ch5
Ch6
Sense +
Sense +
Sense +
Ch16
Ch17
Ch18
Sense +
Sense +
Sense +
Ch16
Ch17
Ch18
Sense -
Sense -
Sense -
Ch16
Ch16
Ch18
Excitation +
Excitation -
Ex.Sense +
Ch20
Ch20
Ch22
Ex.Sense +
Ex.Sense -
Ex.Sense +
Ch20
Ch21
Ch22
Sense -
Sense -
Sense -
Ch20
Ch21
Ch22
Sense +
Sense +
Sense +
172 Advanced Programming with the VT1529B
The field wiring for the VT1586A, when used with the VT1529B, is
different from the wiring of the VT1586A when used stand-alone. In
particular, with the VT1529B option 002 VT1529B-to-VT1586A cable, the
G (Guard) terminals of the VT1586A are redefined to be the excitation
source and excitation sense terminals for the reference thermistor(s).
Figure 5-4 shows the VT1586A front panel connections. Note that the
Sense + and - terminals for the channels are the same using the VT1586A.
Ch3
Sense +
Ch3
Sense -
Ch2
Ex.Sense -
Ch6
Ex.Sense -
Ch7
Sense -
Ch7
Sense +
Ch19
Sense +
Ch19
Sense -
Ch18
Ex.Sense -
Ch22
Ex.Sense -
Ch23
Sense -
Right Side
Ch23
Sense +
Figure 5-4. VT1586A Terminal Panel Connections
When using the VT1586A with the VT1529B to measure temperature,
instead of using a current source to excite the isothermal reference
thermistor, use a voltage source and a resistor divider network. The
excitation voltage supply that the VT1529B is connected to is routed
through the VT1529A-to-VT1586A cable and is made available on the four
Excitation + and - terminals on the VT1586A for use with the divider. The
recommended thermistor divider circuit is shown in Figure 5-5 and the
recommended field wiring for the divider in shown in Figure 5-6. Note that
the excitation voltage is not being connected to a measurement channel.
Instead, the same dedicated excitation measurement channel on the
VT1529B can be used that was use for strain.
Note
The Excitation Sense + and - channels shown in Figure 5-4 are normally
not used. They can be used to "wrap around" the excitation voltage outputs
on the VT1586A to the corresponding measurement channel on the
VT1529B, if necessary.
NOT USED
Ch8
Sense +
Ch8
Sense -
Ch8
Excitation +
Ch12
Ex.Sense +
Ch12
Sense -
Ch12
Left Side
Sense +
NOT
NOT USED
USED
Ch24
Sense +
Ch24
Sense -
Ch24
Excitation +
Ch28
Ex.Sense +
Ch28
Sense -
Ch28
Sense +
Ch9
Ch10
Ch11
Sense +
Sense +
Sense +
Ch10
Ch11
Ch9
Sense -
Sense -
Sense -
Ch10
Ch10
Ch8
Ex.Sense +
Ex.Sense -
Excitation -
Ch12
Ch14
Ch14
Ex.Sense -
Ex.Sense +
Ex.Sense -
Ch14
Ch15
Ch13
Sense -
Sense -
Sense -
Ch13
Ch14
Ch15
Sense +
Sense +
Sense +
Ch25
Ch26
Ch27
Sense +
Sense +
Sense +
Ch25
Ch26
Ch27
Sense -
Sense -
Sense -
Ch24
Ch26
Ch26
Excitation -
Ex.Sense +
Ex.Sense -
Ch28
Ch30
Ch30
Ex.Sense -
Ex.Sense +
Ex.Sense -
Ch29
Ch30
Ch31
Sense -
Sense -
Sense -
Ch30
Ch31
Ch29
Sense +
Sense +
Sense +
Chapter 5

Advertisement

Table of Contents
loading

Table of Contents