Fibre Channel driver

Table 28
lists error log messages common to both Fibre Channel ports, 1 (FC1) and 2 (FC2). Log
messages beginning with #0 apply to Fibre Channel port 1 (FC1), and log messages beginning with
#1 apply to Fibre Channel port 2 (FC2).
Table 28 FC driver Error log messages
ID
Log message
#%d: QLUtmReceiveIo: Path invalid/FW No resource
106583
count %x
106589
#%d: QLIoctlEnable: Adapter disabled
106590
#%d: QLIoctlEnable: Initialize FW error
#%d: QLIoctlRunDiag: Diagnostic loopback command
106592
failed %x %x %x %x
106593
#%d: QLIoctlDisable: Re-initialize adapter failed
106595
#%d: QLUtmReceiveIo: Invalid VP Loop Id 0x%x
106803
#%d: QLIsrEventHandler: Link down (%x)
#%d: QLIsrEventHandler: Unexpected async event (%x),
106813
MB1=%x, MB2=%x, MB3=%x, MB4=%x, MB5=%x,
MB6=%x, MB7=%x
106846
#%d: QLProcessResponseQueueFS: TRB is NULL: %d
106851
#%d: QLTimer: Heartbeat failed
No.
Description
The FC processor received a
SCSI command for an un-
87
known target path or has run
out of resources to execute
additional commands.
The FC processor was dis-
93
abled by an IOCTL request
to the driver.
The FC processor firmware
failed initialization. The re-
94
quest to initialize was re-
ceived by the driver in an
IOCTL request.
The FC processor failed the
96
external loopback test.
The FC processor failed to
97
re-initialize in response to an
IOCTL disable request.
99
Invalid Virtual Port loop ID
The FC processor reported a
link down condition. Table
B-10. Fibre Channel
307
Driver Error Log Messages
(Continued) ID Log Messages
No.
The FC processor reported
an unexpected asynchronous
event. The mailbox registers
317
provide status, event code,
and data related to the
event.
FCIP Response queue entry
350
TRB pointer is NULL
FC firmware failed to re-
spond to a keep alive com-
355
mand. FC firmware will be
restarted.
IP Distance Gateway User Guide