ID
Log message
#%d: QLUtmProcessResponseQueue: Immediate data addr
74069
%08x:%08x in unsupported PduType
#%d: QLiSNSEnableCallback: iSNS Server TCP Connect
74241
failed
74577
#%d: QLIsrDecodeMailbox: NVRAM invalid
#%d: QLIsrDecodeMailbox: AEN %04x, Duplicate IP ad-
74580
dress detected, MB[1-5] %04x %04x %04x %04x %04x
74587
#%d: QLIsrDecodeMailbox: Link down
74620
#%d: QLProcessAen: Invalid event %x
#%d: QLReadyTimer: Adapter missed heartbeat for %d
74656
seconds. Time left %d
#%d: QLReadyTimer: Adapter missed heartbeat for 0x%x
74659
seconds
#%d: QLTimer: Abort pTpb=%p, Type %x, Timeout 0x%x
74661
DrvCount 0x%x, DdbIndex 0x%x
#%d: QLReadyTimer: MBOX_CMD %04x %04x %04x
74663
%04x %04x %04x %04x %04x timed out
74665
#%d: QLReadyTimer: QLiSNSReenable failed
74705
#%d: QLProcessSystemError: Restart RISC
#%d: QLInitializeFW: MBOX_CMD_INITIALIZE_FIRMWARE
74746
failed %04x %04x %04x %04x %04x %04x
#%d: QLUpdateInitiatorData: No more room in Initiator
74784
Database
74800
#%d: QLSetTargetData: No more room in Target Database
146
Log data
No.
Description
Driver received an unsuppor-
341
ted pdu type with immediate
data address
The iSCSI processor could not
513
connect with the iSNS.
The iSCSI processor reported
that the iSCSI port NVRAM
849
contains invalid data (check-
sum error).
Duplicate IP address is detec-
852
ted on iscsi port %d
The iSCSI processor reported
859
a link down condition.
Driver received an invalid
892
event from iScsi FW
The driver failed to receive a
heartbeat from the iSCSI pro-
928
cessor for the specified num-
ber of seconds.
Driver did not receive a
931
heartbeat event from iScsi FW
The driver timed out an iSCSI
933
processor operation and is
aborting the operation.
The driver timed out an iSCSI
935
processor mailbox command.
The driver timed out while at-
937
tempting to reconnect with the
iSNS.
Driver detected an error that
977
requires iSCSI FW to be restar-
ted
1018
iScsi FW failed to initialize
The driver's initiator database
is full. The driver is capable
of storing 1024 iSCSI initiat-
1056
ors in its database. Use the
CLI or GUI to remove un-
wanted/unused iSCSI initiat-
ors.
The driver's target database
is full. Use the CLI or GUI to
1072
remove unwanted/unused
iSCSI targets.

Advertisement

Table of Contents
loading

Table of Contents