C-series Fibre Channel switch parameters
Execute the commands in
commands based on the storage system, one per line in the order listed below.
Table 14 Settings for C-series switches
nl
Command
C-Switch# config
C-Switch(config)# in-order-guarantee VSAN #
nl
(where # stands for all VSANs that use the FCIP link)
C-Switch(config)# vsan database
C-Switch(config-vsan-db)# vsan # loadbalancing src-dst-
id
nl
(where # stands for all VSANs that use the FCIP link)
C-Switch(config-vsan-db)# vsan # loadbalancing src-dst-
ox-id
nl
(where # stands for all VSANs that use the FCIP link)
C-Switch(config-vsan-db)# exit
C-Switch(config)# exit
C-Switch# copy run start
Configuring the mpx110 for connecting remote SANs
Verify the SAN configuration requirements:
•
At least one FC port of each mpx110 should be connected to an FC SAN.
•
Use FC WWPN-based zoning.
Table 14
for each VSAN that will use the FCIP link. Enter configuration
HP Continuous Access stor-
age system
EVA and XP
EVA and XP
EVA and XP
EVA only
XP only
EVA and XP
EVA and XP
EVA and XP
IP Distance Gateway User Guide
47