Quickfind Diagnostic Panel Leds; Front Control Panel Led Definitions; Quickfind Diagnostic Panel Led Definitions - HP rp4410 Service Manual

User service guide, fifth edition - hp 9000 rp4410/4440
Hide thumbs Also See for rp4410:
Table of Contents

Advertisement

Table 5-3 Front Control Panel LED Definitions
LED/Button
System LED
System LED
System LED
System LED
System LED
Power LED
Power LED
Power LED
Disk LED
Thermal LED
Thermal LED
Locator
LED/button

QuickFind Diagnostic Panel LEDs

The QuickFind diagnostic panel is located under the top cover and is attached to the top of the
power supply cage. The following definitions describe the status of the various LEDs and what
is wrong with the indicated component.
NOTE:
LED behavior is based on firmware. For changes in LED behavior, see your server
firmware release notes.
Table 5-4
lists the QuickFind diagnostic panel LED definitions.
Table 5-4 QuickFind Diagnostic Panel LED Definitions
Item
Processor
Subsystem
I/O VRM
CPU VRM
Fan module
140
Troubleshooting
State
Flash Rate
Running
Steady
Booting
Flashing at 0.5
Hz
Attention
Flashing at 1 Hz
Fault
Flashing at 2 Hz
Off
Off
On
Steady
On
Flashing at 1 Hz
Off
Off
Active
Flashing at rate
of disk activity
OK
Steady
Warning
Flashing at 1 Hz
Active
Flashing at 1 Hz
LED 0
LED 1
LED 2
Socket 0
Socket 1
Socket 2
CPU
Memory
I/O board
board
board
n/a
n/a
n/a
n/a
n/a
n/a
0
1
2
Color
Description
Green
System normal. OS up and running.
Green
OS booting or at BCH.
Yellow
Warning. System needs attention. Redundancy
lost, component failure pending. (Additional
information can be found in the System Log).
Red
Hard fault, system halted.
N/A
System off.
Green
Power normal.
Yellow
Housekeeping voltage present.
Off
Power off.
Green
Disk activity.
Green
Thermal OK.
Yellow
Thermal warning.
Blue
System locator LED can be remotely or locally
activated/deactivated.
LED 3
Details
Socket 3
If the System LED (on front panel) is in the attention
or fault state and the processor LED is on, then the
processor or voltage regulator has failed and the
processor module in the specified socket needs to be
replaced. If the thermal LED is in the warning or
critical state and the processor LED is on, then the
processor exceeded the warning or critical level
n/a
A soldered voltage regulator has failed and the
specified board must be replaced
n/a
n/a
n/a
n/a
n/a
One or both fans in a fan module have failed and the
module must be replaced. Fan 2 is in front of the
power supplies

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rp44409000 rp4410-49000 rp4440-89000 rp44109000 rp4440