The following controller events could occur:
Event
Type of
ID
Event
388
Critical
389
Warning
390
Informational
391
Critical
395
Critical
396
Informational
397
Informational
398
Critical
399
Serious
Table 1
Types of Events
6.9.4

Event Severity

Each event message is classified into one of five different severities which corresponds to a colored icon:
6.9.4.1

Serious Icon:

A critical error or major device failure has occurred.
User action is needed but data or access to data may have already been lost.
User may have to call for service or replace hardware.
Resources in a critical state should be considered Down according to RAB guidelines.
6.9.4.2
Icon:
Error
A serious error or device failure has occurred.
130
Description
Controller is dead. System is disconnecting
from this controller.
Controller has been reset.
Controller is found.
Controller is gone. System is disconnecting
from this controller.
Controller is gone. System is disconnecting
from this controller.
Controller powered on.
Controller is online.
Controller is gone. System is disconnecting
from this controller.
Controller's partner is gone, controller is in
failover mode now.
What to Do About It
Replace the controller and apply a
configuration.
Check the controller's configuration and
restore as necessary. (Resetting a controller
may cause loss of data or loss of access to
data.)
Nothing.
Replace the controller and apply a
configuration.
Replace the controller and apply a
configuration.
Nothing.
Nothing.
Replace the controller and apply a
configuration.
Replace the controller, apply a configuration,
and return the controller to duplex mode.