102
103
104
128
129
130
131
Table 2
RAID Controller Event Codes
© 2003, Adaptec, Inc.
Name
MLXEV_SYSDEV_PFA_STOP
Description Finished predicted failure analysis on every physical disk.
Cause
Controller finished predicted failure analysis on the physical disks.
Action
None
Address
ctl: 0
Severity
4 (Information)
Source
ExPro
Name
MLXEV_SYSDEV_BKGND_PATROL_START
Description Background patrol started or was resumed.
Cause
Background patrol started.
Action
None
Address
ctl: 0
Severity
4 (Information)
Source
ExPro
Name
MLXEV_SYSDEV_BKGND_PATROL_STOP
Description Background patrol has found no more physical disks or was
commanded to stop.
Cause
Background patrol finished or was stopped.
Action
None
Address
ctl: 0
Severity
4 (Information)
Source
ExPro
Name
MLXEV_SYSDEV_CHECK_START
Description Consistency check has started.
Cause
User started a consistency check.
'raidbld' started a consistency check.
Action
None
Address
ctl: 0 logdrv: 15
Severity
4 (Information)
Source
ExPro InPro
Name
MLXEV_SYSDEV_CHECK_DONE
Description Consistency check has finished.
Cause
Consistency check completed successfully without detecting any errors.
Action
None
Address
ctl: 0 logdrv: 15
Severity
4 (Information)
Source
ExPro InPro
Name
MLXEV_SYSDEV_CHECK_CANCELED
Description Consistency check is cancelled.
Cause
User cancelled the consistency check.
Action
Restart consistency check, if required.
Address
ctl: 0 logdrv: 15
Severity
2 (Error)
Source
ExPro InPro
Name
MLXEV_SYSDEV_CHECK_ERROR
Description Consistency check on logical drive error.
Cause
Inconsistent data were found.
Bad sectors were found.
A physical disk reliability problem.
Action
See bad block and request sense table for more information.
Address
ctl: 0 logdrv: 15
Severity
2 (Error)
Source
ExPro InPro