412
413
414
415
416
417
418
Table 2
RAID Controller Event Codes
© 2003, Adaptec, Inc.
Name
MLXEV_CTLDEV_NORMAL_CACHE_MODE
Description Controller entered normal cache mode.
Cause
–
Action
None
Address
ctl: 0
Severity
4 (Information)
Source
ExPro
Name
MLXEV_CTLDEV_DEV_START_CMPLT
Description Controller device start complete.
Cause
–
Action
None
Address
ctl: 0
Severity
4 (Information)
Source
ExPro
Name
MLXEV_CTLDEV_SOFT_ECC_CORRECTED
Description Soft ECC error corrected.
Cause
Faulty memory module.
Action
Replace memory module
Address
ctl: 0
Severity
2 (Error)
Source
ExPro InPro
Name
MLXEV_CTLDEV_HARD_ECC_CORRECTED
Description Hard ECC error corrected.
Cause
Faulty memory module.
Action
Replace memory module.
Address
ctl: 0 chn: 13 tgt: 14
Severity
2 (Error)
Source
ExP_old InPro
Name
MLXEV_CTLDEV_BBU_RECOND_NEEDED
Description Battery recondition suggested.
Cause
–
Action
None
Address
ctl: 0
Severity
4 (Information)
Source
ExPro
Name
MLXEV_CTLDEV_REMOVED_PTNR
Description Controller's partner has been removed.
Cause
Controller was removed or controller was ordered shutdown.
Action
None
Address
ctl: 0
Severity
3 (Warning)
Source
ExP_old
Name
MLXEV_CTLDEV_BBU_OUT_OF_SERVICE
Description BBU out of service.
Cause
BBU will not be able to power the cache if ac power fails.
Firmware will switch WriteBack logical drives to WriteThrough.
Action
Replace BBU battery.
Address
ctl: 0
Severity
2 (Error)
Source
InPro
167