Adaptec MAN-00005-UG Installation And User Manual page 139

Spheras storage director
Table of Contents

Advertisement

52
53
54
55
56
57
58
Table 2
RAID Controller Event Codes
140
Name
MLXEV_PHYSDEV_REBUILD
Description Physical disk status changed to rebuild.
Cause
Action
None
Address
ctl: 0 chn: 13 tgt: 14
Severity
2 (Error)
Source
ExPro
Name
MLXEV_PHYSDEV_ID_MISMATCH
Description Physical device ID did not match.
Cause
Action
None
Address
ctl: 0 chn: 13 tgt: 14
Severity
3 (Warning)
Source
ExP_old
Name
MLXEV_PHYSDEV_FAILED_START
Description Physical disk failed to start.
Cause
Action
Reseat the physical disk.
Replace the physical disk.
Address
ctl: 0 chn: 13 tgt: 14
Severity
2 (Error)
Source
ExPro
Name
MLXEV_PHYSDEV_OFFSET_SET
Description Physical disk negotiated different offset than configured.
Cause
Action
None
Address
ctl: 0 chn: 13 tgt: 14
Severity
3 (Warning)
Source
ExP_old
Name
MLXEV_PHYSDEV_SET_BUS_WIDTH
Description Physical disk negotiated different bus width than configured.
Cause
Action
None
Address
ctl: 0 chn: 13 tgt: 14
Severity
3 (Warning)
Source
ExP_old
Name
MLXEV_PHYSDEV_MISSING_ONSTARTUP
Description Physical disk missing on startup.
Cause
Physical disk missing.
Action
Replace the physical disk or power-on all enclosures.
Address
ctl: 0 chn: 13 tgt: 14
Severity
1 (Serious)
Source
ExP_old InPro
Name
MLXEV_PHYSDEV_REBUILD_START_FAILED
Description Rebuild startup failed due to lower physical disk capacity.
Cause
Physical disk capacity not sufficient for rebuild.
Action
Replace with a physical disk having sufficient capacity.
Address
ctl: 0 chn: 13 tgt: 14
Severity
2 (Error)
Source
InPro