Table 2
RAID Controller Event Codes
© 2003, Adaptec, Inc.
Name
MLXEV_FMTHEAT_BAD
Description Over temperature. Temperature is above 70 °C.
Cause
Room temperature is too high.
Fan failure.
Sensor failure.
Action
Turn off the system and let it to cool down.
Adjust the room temperature.
Address
ctl: 0 chn: 13 tgt: 14 Heat Sensor: 15
Severity
1 (Serious)
Source
InP_old
Name
MLXEV_FMTHEAT_CRITICAL
Description Temperature is above 50 °C.
Cause
Room temperature is high.
Fan failure.
Action
Replace fan.
Turn off the system.
Adjust the room temperature.
Address
ctl: 0 enclosure: 13 unit: 14
Severity
3 (Warning)
Source
ExP_old InP_old
Name
MLXEV_FMTHEAT_OK
Description Normal temperature has been restored.
Cause
Faulty fan has been replaced.
Room temperature was reduced.
Action
None
Address
ctl: 0 enclosure: 13 unit: 14
Severity
4 (Information)
Source
ExPro InP_old
Name
MLXEV_AEMI_OVER_TEMPERATURE
Description Over temperature.
Cause
Room temperature is too high.
Fan failure.
Action
Turn off the system and let it to cool down.
Adjust the room temperature.
Address
ctl: 0 chn: 13 tgt: 14 Heat Sensor: 15
Severity
1 (Serious)
Source
InP_old
Name
MLXEV_FMTHEAT_NOTPRESENT
Description Storage cabinet temperature sensor is not present.
Cause
Enclosure management connection is broken.
Management hardware failure.
Sensor is not present.
Action
Refer to enclosure manufacturer's service manual.
Address
ctl: 0 enclosure: 13
Severity
4 (Information)
Source
ExP_old InP_old
Name
MLXEV_FMTSTWK_FAILED
Description Storage Works enclosure reported failure state.
Cause
Power supply failed.
Fan failure.
Cabinet is too hot.
Action
Refer to enclosure manufacturer's service manual.
Address
ctl: 0 chn: 13
Severity
1 (Serious)
Source
InPro