Adaptec MAN-00005-UG Installation And User Manual page 151

Spheras storage director
Table of Contents

Advertisement

146
147
148
149
150
151
Table 2
RAID Controller Event Codes
152
Name
MLXEV_SYSDEV_INIT_CANCELED
Description Logical drive initialization cancelled.
Cause
User cancelled the initialization.
Action
Restart initialization if required.
Address
ctl: 0 logdrv: 15
Severity
2 (Error)
Source
ExPro InPro
Name
MLXEV_SYSDEV_INIT_FAILED
Description Logical drive initialization failed.
Cause
One/multiple physical device(s) failed.
Controller has been removed.
Controller has been powered off.
Action
Refer to the device failure event.
Address
ctl: 0 logdrv: 15
Severity
2 (Error)
Source
ExPro InPro
Name
MLXEV_SYSDEV_FOUND
Description A logical drive has been found.
Cause
A new configuration has been added.
MORE completed.
A new controller has been plugged in.
Controller has been powered on.
System has rebooted.
Action
None
Address
ctl: 0 logdrv: 15
Severity
4 (Information)
Source
InPro
Name
MLXEV_SYSDEV_GONE
Description A logical drive has been deleted.
Cause
A new configuration has been added.
A new logical device has been deleted.
Controller has been removed.
Controller has been powered off.
Action
None
Address
ctl: 0 logdrv: 15
Severity
4 (Information)
Source
InPro
Name
MLXEV_SYSDEV_EXPANDCAPACITY_START
Description Expand capacity started.
Cause
User started the online RAID expansion operation.
Action
None
Address
ctl: 0 logdrv: 15
Severity
4 (Information)
Source
ExPro InPro
Name
MLXEV_SYSDEV_EXPANDCAPACITY_DONE
Description Expand capacity completed.
Cause
Online RAID expansion completed.
Action
None
Address
ctl: 0 logdrv: 15
Severity
4 (Information)
Source
ExPro InPro
Spheras Storage Director Installation and User Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

Spheras storage director

Table of Contents