Table 2
RAID Controller Event Codes
160
Name
MLXEV_ENCLHEAT_BAD
Description Temperature is over safe limit. Failure imminent.
Cause
Room temperature is too high.
Fan failure.
Sensor failure.
Action
Turn off the system and let it to cool down.
Adjust the room temperature.
Address
ctl: 0 enclosure: 13 unit: 14
Severity
1 (Serious)
Source
ExPro InPro
Name
MLXEV_ENCLHEAT_CRITICAL
Description Temperature is above working limit.
Cause
Room temperature is too high.
Fan failure.
Action
Adjust the room temperature.
Replace fan.
Turn off the system.
Address
ctl: 0 enclosure: 13 unit: 14
Severity
2 (Error)
Source
ExPro InPro
Name
MLXEV_ENCLHEAT_OK
Description Normal temperature has been restored.
Cause
Faulty fan has been replaced.
Room temperature was reduced.
Action
None
Address
ctl: 0 enclosure: 13 unit: 14
Severity
4 (Information)
Source
ExPro InPro
Name
MLXEV_ENCLHEAT_NOTPRESENT
Description Temperature sensor is not present.
Cause
Enclosure management connection is broken.
Management hardware failure.
Sensor is not present.
Action
Refer to enclosure manufacturer's service manual.
Address
ctl: 0 enclosure: 13 unit: 14
Severity
4 (Information)
Source
ExPro InPro
Name
MLXEV_ENCLACCESS_CRITICAL
Description Enclosure access critical.
Cause
Enclosure management connection is broken.
Management hardware failure.
Action
Refer to enclosure manufacturer's service manual.
Address
ctl: 0 enclosure: 13
Severity
2 (Error)
Source
ExPro InPro
Name
MLXEV_ENCLACCESS_OK
Description Enclosure access has been restored.
Cause
Enclosure has been fixed or replaced.
Action
None
Address
ctl: 0 enclosure: 13
Severity
4 (Information)
Source
ExPro InPro