Table 2
RAID Controller Event Codes
© 2003, Adaptec, Inc.
Name
MLXEV_PHYSDEV_COMMAND_RETRIED
Description SCSI command retried on physical disk.
Cause
The command may have timed out.
Bus reset may have occurred.
Device reset may have occurred.
Action
None
Address
ctl: 0 chn: 13 tgt: 14
Severity
3 (Warning)
Source
InP_old
Name
MLXEV_PHYSDEV_PARITY_ERROR
Description Parity error found.
Cause
A physical device did not generate proper parity.
The controller failed; did not check parity properly.
Cable failed.
Improper cable length.
Another physical device interfered.
Some outside environment affected the data on the cable (such as a
radio frequency signal).
Terminator is not connected.
Improper termination.
Action
Refer to the enclosure manufacturer's service manual.
Address
ctl: 0 chn: 13 tgt: 14
Severity
2 (Error)
Source
ExPro InP_old
Name
MLXEV_PHYSDEV_SOFT_ERROR
Description Soft error found.
Cause
An error was detected by a physical device and data was recovered.
Action
Run consistency check.
If problem occurs frequently, replace the physical device.
Address
ctl: 0 chn: 13 tgt: 14
Severity
3 (Warning)
Source
InP_old
Name
MLXEV_PHYSDEV_MISC_ERROR
Description Miscellaneous error found.
Cause
A physical device reported some error that does not fit in any category.
Read/Write command time out.
Data over run.
Physical device was busy when host attempted to send command.
Action
If problem occurs frequently, replace the physical device.
Address
ctl: 0 chn: 13 tgt: 14
Severity
3 (Warning)
Source
InP_old
Name
MLXEV_PHYSDEV_RESET
Description SCSI device reset.
Cause
Firmware has reset to recover from error.
User has reset.
Action
None
Address
ctl: 0 chn: 13 tgt: 14
Severity
4 (Information)
Source
ExP_old InPro