Adaptec MAN-00005-UG Installation And User Manual page 144

Spheras storage director
Table of Contents

Advertisement

81
82
83
84
85
Table 2
RAID Controller Event Codes
© 2003, Adaptec, Inc.
Name
MLXEV_SYSDEV_REBUILD_FAILED_ON_PARTNER
Description Rebuild stopped on controller failure.
Cause
Rebuild moved to the surviving controller because the partner, which
was running the rebuild, failed.
Action
None.
Address
ctl: 0 logdrv: 15
Severity
4 (Information)
Source
ExPro
Name
MLXEV_SYSDEV_CHECK_CONSISTENCY_FAILED_ON_
PARTNER
Description Check Consistency stopped on controller failure.
Cause
Check Consistency failed because the partner, which was running the
Check Consistency, failed.
Action
Restart the Check Consistency.
Address
ctl: 0 logdrv: 15
Severity
2 (Error)
Source
ExPro
Name
MLXEV_SYSDEV_FOREGROUND_INIT_FAILED_ON_
PARTNER
Description Foreground initialization stopped on controller failure.
Cause
Foreground initialization failed because the partner, which was running
the foreground initialization, failed.
Action
Restart the foreground initialization.
Address
ctl: 0 logdrv: 15
Severity
2 (Error)
Source
ExPro
Name
MLXEV_SYSDEV_BACKGROUND_INIT_FAILED_ON_
PARTNER
Description Background initialization stopped on controller failure.
Cause
Background initialization restarted on the surviving controller because
the partner, which was running the background initialization, failed.
Action
None.
Address
ctl: 0 logdrv: 15
Severity
4 (Information)
Source
ExPro
Name
MLXEV_CFG_COD_GROUP_NOT_INSTALLED_PDD_
USED
Description Configuration group not installed due to physical disk conflict.
Cause
Physical disk already configured in another group.
Unable to map a physical device in this group.
Action
Move to another controller.
Remove one or more existing configuration groups and reboot with this
group.
Address
None.
Severity
4 (Information)
Source
ExPro
145

Advertisement

Table of Contents
loading

This manual is also suitable for:

Spheras storage director

Table of Contents