Table 2
RAID Controller Event Codes
© 2003, Adaptec, Inc.
Name
MLXEV_ENCLFAN_FAILED
Description Fan failure.
Cause
Cable connection broken.
Fan failure
Action
Replace fan.
Address
ctl: 0 enclosure: 13 unit: 14
Severity
1 (Serious)
Source
ExPro InPro
Name
MLXEV_ENCLFAN_OK
Description Fan has been restored.
Cause
Faulty fan has been replaced.
Cable is connected properly.
Action
None
Address
ctl: 0 enclosure: 13 unit: 14
Severity
4 (Information)
Source
ExPro InPro
Name
MLXEV_ENCLFAN_NOTPRESENT
Description Fan is not present.
Cause
Enclosure management connection is broken.
Management hardware failure.
Fan is not present.
Action
Refer to enclosure manufacturer's service manual.
Address
ctl: 0 enclosure: 13 unit: 14
Severity
2 (Error)
Source
ExPro InPro
Name
MLXEV_ENCLPOWER_FAILED
Description Power supply failure.
Cause
Broken cable connection.
Power supply failure.
Action
Refer to enclosure manufacturer's service manual.
Address
ctl: 0 enclosure: 13 unit: 14
Severity
1 (Serious)
Source
ExPro InPro
Name
MLXEV_ENCLPOWER_OK
Description Power supply has been restored.
Cause
Faulty power supply has been replaced.
Action
None
Address
ctl: 0 enclosure: 13 unit: 14
Severity
4 (Information)
Source
ExPro InPro
Name
MLXEV_ENCLPOWER_NOTPRESENT
Description Power supply is not present.
Cause
Enclosure management connection is broken.
Management hardware failure.
Power supply is not present.
Action
Refer to enclosure manufacturer's service manual.
Address
ctl: 0 enclosure: 13 unit: 14
Severity
4 (Information)
Source
ExPro InPro
159