409
410
411
Table 2
RAID Controller Event Codes
166
Name
MLXEV_CTLDEV_BBU_CALIBRATE_ABORT
Description Battery calibration cycle was canceled.
Cause
User canceled the battery calibration cycle.
Action
None
Address
ctl: 0
Severity
4 (Information)
Source
ExPro
Name
MLXEV_CTLDEV_BBU_NO_BATTERY
Description Battery is not present.
Cause
The battery electronics are present, but a battery was not detected.
Action
Install or connect the battery.
Address
ctl: 0
Severity
2 (Error)
Source
ExPro
Name
MLXEV_CTLDEV_CONSERV_CACHE_MODE
Description Controller entered conservative cache mode.
Cause
User changed the setting.
Controller preparing for shutdown.
Battery low.
RAID expansion in process.
Over-temperature condition.
No redundant power.
Power supply failure.
UPS ac failed.
UPS battery low.
Action
If this was an unexpected event, refer to the enclosure manufacturer's
service manual.
Address
ctl: 0 param: 0x2120
Severity
3 (Warning)
Source
ExPro
Paramtype
bitfield
Params
1 : name_FAULT_MANAGEMENT : "Fault Management"
2 : name_INPUT_SIG : "Hardware Input Signal"
4 : name_SHUT_DOWN : "Controller Shut Down"
8 : name_BBU_LOW : "BBU Battery Low"
16 : name_MORE : "More Active"
32 : name_OVER_TEMP : "Over Temperature"
64 : name_NON_REDUN_POWER : "Non-redundant Power"
128 : name_POWER_SUPPLY_FAIL : "Power Supply Failed"
256 : name_UPS_AC_FAIL : "UPS AC Failed"
512 : name_UPS_BAT_LOW : "UPS Battery Low"