Adaptec MAN-00005-UG Installation And User Manual page 138

Spheras storage director
Table of Contents

Advertisement

46
47
48
49
50
51
Table 2
RAID Controller Event Codes
© 2003, Adaptec, Inc.
Name
MLXEV_PHYSDEV_NOTRDY_DEAD
Description A physical disk failed because device is not ready.
Cause
Physical disk not spinning, just turned bad.
Power to the physical disk failed.
Action
Replace physical disk and rebuild it.
Check power and rebuild device.
Address
ctl: 0 chn: 13 tgt: 14
Severity
1 (Serious)
Source
InPro
Name
MLXEV_PHYSDEV_MISSING_DEAD
Description A physical disk failed because the physical disk was not found on start
up.
Cause
Physical disk not connected.
Physical disk not responding.
Clear configuration suspend mode command was invoked.
Action
Check setup.
Check the startup option parameters on the system.
Address
ctl: 0 chn: 13 tgt: 14
Severity
1 (Serious)
Source
InPro
Name
MLXEV_PHYSDEV_CODWRFAIL_DEAD
Description A physical disk failed because write operation of the 'Configuration On
Disk' failed.
Cause
Failed physical disk.
Device write protected.
Action
Replace physical disk and rebuild it.
Check the startup option parameters on the system.
Address
ctl: 0 chn: 13 tgt: 14
Severity
1 (Serious)
Source
InPro
Name
MLXEV_PHYSDEV_BDTWRFAIL_DEAD
Description A physical disk failed because write operation of 'Bad Data Table'
failed.
Cause
Failed physical disk.
Device write protected.
Action
Replace physical disk and rebuild it.
Check the startup option parameters on the system.
Address
ctl: 0 chn: 13 tgt: 14
Severity
1 (Serious)
Source
InPro
Name
MLXEV_PHYSDEV_OFFLINE
Description Physical disk status changed to offline.
Cause
Action
None
Address
ctl: 0 chn: 13 tgt: 14
Severity
2 (Error)
Source
ExPro
Name
MLXEV_PHYSDEV_STANDBY
Description Physical disk status changed to Hot Spare.
Cause
Action
None
Address
ctl: 0 chn: 13 tgt: 14
Severity
4 (Information)
Source
ExPro
139