Table 2
RAID Controller Event Codes
162
Name
MLXEV_ENCLOSURE_SHUTDOWN
Description Physical disks in enclosure are being spundown.
Cause
Enclosure temperature is too high.
Fan failure.
Sensor failure.
Action
Turn off the enclosure and repair the problem causing the critical over-
temperature condition.
After the problem is repaired, recover by power cycling the entire
system including the controllers.
Address
ctl: 0 enclosure: 13 unit: 14
Severity
1 (Serious)
Source
ExPro
Name
MLXEV_ENCLCOLD_WARN
Description Temperature is below working limit.
Cause
Room temperature is too low.
Sensor failure.
Action
Inspect the enclosure environment for proper operation and repair as
required.
Increase the room temperature as required.
Address
ctl: 0 enclosure: 13
Severity
2 (Error)
Source
ExPro
Name
MLXEV_ENCLCOLD_FAIL
Description Temperature is under safe limit. Failure is imminent.
Cause
Room temperature is too low.
Sensor failure.
Action
Inspect the enclosure environment for proper operation and repair as
required.
Increase the room temperature as required.
Address
ctl: 0 enclosure: 13
Severity
1 (Serious)
Source
ExPro
Name
MLXEV_SYSTEM_STARTED
Description Array management server software started successfully.
Cause
The server system (or array management utility server) started.
Action
If you did not expect a system reboot, investigate.
Address
None
Severity
4 (Information)
Source
ExPro InP_old
Name
MLXEV_CTLDEV_WRITEBACK_ERROR
Description Write back error.
Cause
Data cache write failed.
Action
The data may have been lost.
Restore the data from a backup.
Address
ctl: 0
Severity
2 (Error)
Source
InP_old
Name
MLXEV_CTLDEV_STATE_TABLE_FULL
Description Internal log structures getting full; PLEASE SHUTDOWN AND
RESET THE SYSTEM IN THE NEAR FUTURE.
Cause
Too many configuration changes occurred since the last boot.
Action
Reboot the system by power cycling when ever convenient.
Address
ctl: 0
Severity
3 (Warning)
Source
Unspecified