Adaptec MAN-00005-UG Installation And User Manual page 172

Spheras storage director
Table of Contents

Advertisement

440
441
512
513
514
515
516
Table 2
RAID Controller Event Codes
© 2003, Adaptec, Inc.
Name
MLXEV_CTLDEV_MIRROR_RACE_TABLE_ERROR
Description Error in mirror race table.
Cause
Logical drives appear in the mirror race table that do not exist in the
configuration.
Possible data integrity issue.
Action
Check configuration for accuracy, run consistency check and restore
consistency.
Address
ctl: 0 logdrv: 15
Severity
1 (Serious)
Source
ExPro
Name
MLXEV_CTLDEV_STOP_REJECTED
Description A replacement controller attempted to stop the surviving controller.
Cause
Incompatible replacement controller firmware or hardware.
Action
Obtain a compatible replacement controller.
Address
ctl: 0
Severity
2 (Error)
Source
ExPro
Name
MLXEV_SYSTEM_STARTED_NEW
Description System started.
Cause
The server system (or array management utility server) started.
Action
If you did not expect a system reboot, investigate.
Address
Severity
4 (Information)
Source
InPro
Name
MLXEV_SYSTEM_SIZE_TABLE_FULL
Description Size table full.
Cause
Too much physical device size information is defined.
Action
Remove unused device information from this system.
Address
None
Severity
4 (Information)
Source
InPro
Name
MLXEV_SYSTEM_USER_LOGGED_IN
Description User logged in.
Cause
An array management utility user logged in on the server system.
Action
Not available.
Address
None
Severity
4 (Information)
Source
InPro
Name
MLXEV_SYSTEM_USER_LOGGED_OUT
Description User logged out.
Cause
An array management utility user logged out of the server system.
Action
Not available.
Address
None
Severity
4 (Information)
Source
InPro
Name
MLXEV_SYSTEM_ALIVE
Description Server alive.
Cause
Reconnected to server.
Server rebooted.
Action
None
Address
None
Severity
4 (Information)
Source
InPro
173