Table 2
RAID Controller Event Codes
© 2003, Adaptec, Inc.
Name
MLXEV_CFG_COD_IMPORT_FAILED
Description Configuration on disk import failed.
Cause
The controller could not import the configuration.
Action
None
Address
ctl: 0
Severity
3 (Warning)
Source
ExP_old
Name
MLXEV_DEBUG_DUMP_GENERATED
Description A debug dump exists on this system.
Cause
The controller aborted and created debug dump information.
Action
Contact field support for assistance in retrieving the data.
Address
ctl: 0 abort code: 0x1314
Severity
4 (Information)
Source
ExPro
Name
MLXEV_DEBUG_DUMP_GENERATED_PARTNER
Description A debug dump exists on this system.
Cause
The partner controller aborted and created debug dump information.
Action
Contact field support for assistance in retrieving the data.
Address
ctl: 0 abort code: 0x1314
Severity
4 (Information)
Source
ExPro
Name
MLXEV_CFG_COD_NOT_FOUND
Description Valid configuration on disk not found.
Cause
No physical disk contains a valid configuration on disk area.
Physical disks were never written with a configuration on disk.
Physical disks were replaced while the controller system was offline.
Action
If you expected the configuration on disk, investigate.
Address
ctl: 0
Severity
4 (Information)
Source
ExPro
Name
MLXEV_CFG_COD_LUN_MAP_NOT_FOUND
Description Valid SANMap was not found in the configuration on disk.
Cause
No physical disk contains a valid SANMap in the configuration on disk
area.
Physical disks from a system that did not use SANMapping may have
been installed.
Action
If you expected a valid SANMap, investigate.
Address
ctl: 0
Severity
4 (Information)
Source
ExPro