275
Table 2
RAID Controller Event Codes
156
Name
MLXEV_AEMI_FAN_FAILED
Description Fan failure.
Cause
Cable connection is broken.
Fan failure.
Action
Replace fan.
Address
ctl: 0 chn: 13 tgt: 14 Fan: 15
Severity
1 (Serious)
Source
InP_old
Name
MLXEV_FMTFAN_NOTPRESENT
Description Storage cabinet fan is not present.
Cause
Enclosure management connection is broken.
Management hardware failure.
Fan is not present.
Action
Refer to the enclosure manufacturer's service manual.
Address
ctl: 0 enclosure: 13
Severity
4 (Information)
Source
ExP_old InP_old
Name
MLXEV_FMTPOWER_FAILED
Description Power supply failure.
Cause
Broken cable connection.
Power supply failure.
Action
Reconnect cable or replace the power supply as required.
Address
ctl: 0 enclosure: 13 unit: 14
Severity
1 (Serious)
Source
ExP_old InP_old
Name
MLXEV_FMTPOWER_OK
Description Power supply has been restored.
Cause
Faulty power supply has been replaced.
Action
None
Address
ctl: 0 enclosure: 13 unit: 14
Severity
4 (Information)
Source
ExP_old InP_old
Name
MLXEV_AEMI_PWR_SUPPLY_FAILED
Description Power supply failure.
Cause
Broken cable connection.
Power supply failure.
Action
Reconnect cable or replace the power supply as required.
Address
ctl: 0 chn: 13 tgt: 14 Power Supply: 15
Severity
1 (Serious)
Source
InP_old
Name
MLXEV_FMTPOWER_NOTPRESENT
Description Storage cabinet power supply is not present.
Cause
Management connection is broken.
Management hardware failure.
Power supply is not present.
Action
Refer to the enclosure manufacturer's service manual.
Address
ctl: 0 enclosure: 13
Severity
4 (Information)
Source
ExP_old InP_old