Table 2
RAID Controller Event Codes
146
Name
MLXEV_CFG_COD_GROUP_NOT_INSTALLED_LDD_
USED
Description Configuration group not installed due to logical drive conflict.
Cause
Logical drive already configured in another group.
Unable to install all the logical drives in the group.
Action
Move to another controller.
Remove one or more existing configuration groups and reboot with this
group.
Address
None.
Severity
4 (Information)
Source
ExPro
Name
MLXEV_CFG_COD_GROUP_NOT_INSTALLED_SAN_MAP_CO
NFLICT
Description Configuration group not installed due to SAN map conflict.
Cause
SAN map conflicted with that of another installed group.
Action
Move to another controller.
Remove one or more existing configuration groups and reboot with this
group.
Address
None.
Severity
4 (Information)
Source
ExPro
Name
MLXEV_CFG_COD_GROUP_NOT_INSTALLED_FOREIGN
Description Foreign configuration group not installed.
Cause
Foreign COD group found but not installed.
Action
Move to another controller
Remove native configuration group and reboot with foreign group.
Address
None.
Severity
4 (Information)
Source
ExPro
Name
MLXEV_CFG_COD_GROUP_NOT_INSTALLED_ALL_BAD_FOR
EIGN
Description No configuration group installed.
Cause
All configuration groups are foreign and clash.
Controllers may have changed.
Action
Move to another controller
Re-insert original controllers or remove some groups and reboot with
one group.
Address
None.
Severity
4 (Information)
Source
ExPro
Name
MLXEV_PPILOT_SECONDARY_DISK_NOT_FOUND
Description A secondary logical drive was not found during initialization.
Cause
PATHPilot reported a secondary logical drive was lost during power
cycle.
Action
Investigate possible causes such as cabling, controller failure, or HBA
failure.
Address
PATHpilot: Last HBTL: 12,13,14,15
Severity
4 (Information)
Source
PATHpilot