Adaptec MAN-00005-UG Installation And User Manual page 132

Spheras storage director
Table of Contents

Advertisement

9
10
11
12
13
14
Table 2
RAID Controller Event Codes
© 2003, Adaptec, Inc.
Name
MLXEV_PHYSDEV_REBUILD_ERROR
Description Rebuild stopped with error.
Cause
Due to some unknown error on the controller, rebuild failed.
Action
Try rebuild again.
Address
ctl: 0 chn: 13 tgt: 14
Severity
2 (Error)
Source
ExPro InPro
Name
MLXEV_PHYSDEV_REBUILD_NEWDEV_FAILED
Description Rebuild stopped with error. New physical disk failed.
Cause
New physical disk failed.
New physical disk may not be compatible with MDAC hardware/
firmware.
Action
Replace the physical disk.
Address
ctl: 0 chn: 13 tgt: 14
Severity
2 (Error)
Source
ExPro InPro
Name
MLXEV_PHYSDEV_REBUILD_SYSDEV_FAILED
Description Rebuild stopped because logical drive failed.
Cause
At least one more physical disks failed in the array.
Bad data table overflow.
Action
It may not be possible to recover from this error.
Contact your service representative.
Address
ctl: 0 chn: 13 tgt: 14
Severity
2 (Error)
Source
ExPro InPro
Name
MLXEV_PHYSDEV_DEAD
Description A physical disk has failed.
Cause
A physical disk failed.
A user action caused the physical disk to fail.
Action
Replace the physical disk.
Address
ctl: 0 chn: 13 tgt: 14
Severity
1 (Serious)
Source
ExPro InPro
Name
MLXEV_PHYSDEV_FOUND
Description A new physical disk has been found.
Cause
A physical disk has been powered on.
A new physical disk has been added.
Controller was powered on.
Controller was added.
System has rebooted.
Action
None
Address
ctl: 0 chn: 13 tgt: 14
Severity
4 (Information)
Source
ExPro InPro
Name
MLXEV_PHYSDEV_GONE
Description A physical disk has been removed.
Cause
User removed an unconfigured physical disk.
An unconfigured physical disk failed.
A controller was removed.
A controller powered off.
Action
Replace the device if needed.
Address
ctl: 0 chn: 13 tgt: 14
Severity
4 (Information)
Source
ExPro InPro
133

Advertisement

Table of Contents
loading

This manual is also suitable for:

Spheras storage director