External Network Rs-530 Cable - TANDBERG MXP F8 Administrator's Manual

Table of Contents

Advertisement

MXP
Contents
Introduction
Cable specification
Applies to TANDBERG MXP and Classic Endpoints that supports
External Network

External Network RS-530 Cable

Connector at the Tandberg end:
Female 26pin High Density DSUB Newark P/N 50F2055 or
Equivalent
Connector on RS-530:
DSUB 25 pin Male
Cable length:
1 meter
D14033.06—AUGUST 2010
Getting started
The menu structure
The settings library
Signal Name
Frame Ground
Signal Ground
Send Data (A)
Send Data (B)
Send Timing (A)
Send Timing (B)
Receive Data (A)
Receive Data (B)
Receive Timing (A)
Receive Timing (B)
Terminal Ready (A)
Terminal Ready (B)
Receiver Ready (A)
Receiver Ready (B)
LOS A
Using the system
Physical interfaces
Physical interfaces
Pin-Out on RS-530 Cable
Female
Male
Comments
26 pin DSUB
25 pin DSUB
(Tandberg
RS-530
End)
(DCE End)
Pin Number
Pin Number
1
1
Do not connect shield to FGND
19
7
11
2
Twisted pair
12
14
17
15
Twisted pair
18
12
13
3
Twisted pair
14
16
15
17
Twisted pair
16
9
20
20
21
23
22
8
Twisted pair
23
10
25
18
LOS A Unbalanced