Appendix B Fault Symptom Code (FSC) Dictionary
FSC
Name
26DC
FSC_SERVO_DRIVE_5_
ACCESSED_WHEN_NOT_
FITTED
26DD
FSC_SERVO_DRIVE_6_
ACCESSED_WHEN_NOT_
FITTED
26DE
FSC_SERVO_DRIVE_7_
ACCESSED_WHEN_NOT_
FITTED
26DF
FSC_SERVO_DRIVE_8_
ACCESSED_WHEN_NOT_
FITTED
2700
FSC_DIAG_NO_
RESOURCE
2701
FSC_DIAG_BAD_
MESSAGE
2702
FSC_DIAG_STACK_
TERMINATED
2703
FSC_DIAG_QUEUE_FULL
2704
FSC_DIAG_EMPTY_
INITIATOR_LIST
2800
FSC_EVENT_NO_
RESOURCE
2801
FSC_EVENT_NVR_TOO_
SMALL
138
Description
Attempt to initialize
Drive 5 before it has
become available
Attempt to initialize
Drive 6 before it has
become available
Attempt to initialize
Drive 7 before it has
become available
Attempt to initialize
Drive 8 before it has
become available
PCDIAG task
initialization failed
Unknown or bad
diagnostic message
Current diagnostic
stack has terminated
PCDIAG queue full
Diagnostic command
failure; initiator task
unknown
EVENT LOG task
initialization failed
NVR space allocated to
event log is too small.
See path for required
space and change in
system.
Tandberg Data M-Series User's Guide
FRU Name
Confidence %
Drive 5
50%
Microcode
50%
Drive 6
50%
Microcode
50%
Drive 7
50%
Microcode
50%
Drive 8
50%
Microcode
50%
Microcode
100%
Microcode
100%
Microcode
100%
Microcode
100%