Appendix B Fault Symptom Code (FSC) Dictionary
FSC
Name
2103
FSC_I2C_UNABLE_TO_
SEND_MESSAGE
2104
FSC_I2C_NO_RESPONSE_
FROM_HARDWARE
2105
FSC_I2C_UNKNOWN_
MESSAGE_
DESTINATION
2106
FSC_I2C_MESSAGE_
TOO_BIG
2107
FSC_I2C_RCV_MESSAGE_
TOO_BIG
2108
FSC_I2C_MAILBOX_FULL
2109
FSC_I2C_INVALID_RCV_
ADDRESS
210A
FSC_I2C_STUCK_
INTERRUPT
2200
FSC_UI_NO_RESOURCE
2201
FSC_UI_QUEUE_FULL
2202
FSC_UI_ACTION_
IMPOSSIBLE
2301
FSC_BARCODE_
TIMEOUT
118
Description
Exceeded retry limit
while trying to send
message
Expected response
from hardware was
not received
Message received from
2
I
C bus but destination
is unknown
Message to send over
2
I
C bus is too big (see
path)
Message received over
2
I
C bus is too big
2
I
C mailbox is full
Receiver address in I
message incorrect
Pending interrupt
status not reset
UI task initialization
failed
UI queue full
The UI is not in the
correct state to perform
the requested action
Timed out waiting for
data from barcode
reader
Tandberg Data M-Series User's Guide
FRU Name
Confidence %
2
I
C
100%
2
I
C
100%
2
I
C
100%
2
I
C
100%
2
I
C
100%
2
I
C
100%
2
2
C
I
C
100%
2
I
C
100%
Microcode
100%
Microcode
100%
Microcode
100%