Intel SRSH4 - Server Platform - 0 MB RAM Service Manual page 96

Service guide
Table of Contents

Advertisement

Error
Error message
code
0B92
Internal Use Area of BMC FRU
corrupted.
0B93
BMC SDR Repository empty.
0B94
IPMB signal lines do not respond.
0B95
BMC FRU device failure.
0B96
BMC SDR Repository failure.
0B97
BMC SEL device failure.
0B98
BMC RAM test error.
0B99
BMC Fatal hardware error.
0B9A
BMC not responding.
0B9B
Private I2C bus not responding.
0B9C
BMC internal exception.
0B9D
BMC A/D timeout error.
0B9E
SDR repository corrupt.
0B9F
SEL corrupt.
0BB0
SMBIOS - SROM data read error.
0BB1
SMBIOS - SROM data checksum
bad.
0BC0
POST detected startup failure of 1st
Processor.
0BC1
POST detected startup failure of
2nd Processor.
0BD0
1st SMBus address not
acknowledged.
0BD1
1st SMBus device Error detected.
0BD2
1st SMBus timeout.
0BD3
2nd SMBus address not
acknowledged.
0BD4
2nd SMBus device Error detected.
0BD5
2nd SMBus timeout.
0BD6
3rd SMBus address not
acknowledged.
0BD7
3rd SMBus device Error detected.
0BD8
3rd SMBus timeout.
Recommended Action
All the commands and functions other than the FRU
command and the EMP function can be used. This is
not a fatal error. Turn off the power once and then on
again to restart the server. If the error cannot be
corrected, contact your service representative.
Turn off the power once and then on again to restart
the server. If the error cannot be corrected, contact
your service representative.
All the functions other than the function of accessing to
SMC through IPMB can be used. This is not a fatal
error. Turn off the power once and then on again to
restart the server. If the error cannot be corrected,
contact your service representative.
All the commands and functions other than the FRU
command and the EMP function can be used. This is
not a fatal error. Turn off the power once and then on
again to restart the server. If the error cannot be
corrected, contact your service representative.
Turn off the power once and then on again to start the
server. If the error cannot be corrected, contact your
service representative.
Contact your service representative.
Contact your service representative to replace the
CPU.
Contact your service representative to replace the
board specified in the system event log.
96