Intel SR1520ML - Server System - 0 MB RAM User Manual

Server system
Table of Contents

Advertisement

Quick Links

®
Intel
Server System SR1520ML
User's Guide
A Guide for Technically Qualified Assemblers of Intel® Identified Subassemblies/
Products
Intel Order Number E17409-004

Advertisement

Table of Contents
loading

Summary of Contents for Intel SR1520ML - Server System - 0 MB RAM

  • Page 1 ® Intel Server System SR1520ML User’s Guide A Guide for Technically Qualified Assemblers of Intel® Identified Subassemblies/ Products Intel Order Number E17409-004...
  • Page 2 Intel products are not designed, intended or authorized for use in any medical, life saving, or life sustaining applications or for any other application in which the failure of the Intel product could create a situation where personal injury or death may occur.
  • Page 3: Safety Information

    Safety Information Important Safety Instructions Read all caution and safety statements in this document before performing any of the instructions. See also Intel Server Boards and Server Chassis Safety Information on the ® Intel Server Deployment Toolkit 2.0 CD and/or at http://support.intel.com/support/motherboards/server/sb/cs-010770.htm.
  • Page 4 重要安全指导 在执行任何指令之前,请阅读本文档中的所有注意事项及安全声明。 和/或 http://support.intel.com/support/motherboards/server/sb/CS-010770.htm 上的 Intel Server Boards and Server Chassis Safety Information(《Intel 服务器主板与服务器机箱安全信息》)。 Warnings Heed safety instructions: Before working with your server product, whether you are using this guide or any other resource as a reference, pay close attention to the safety instructions.
  • Page 5 Take care to grip with, but not squeeze, the pliers or other tool you use to remove a jumper, or you may bend or break the pins on the board. ® Intel Server System SR1520ML User’s Guide...
  • Page 6 ® Intel Server System SR1520ML User’s Guide...
  • Page 7: Table Of Contents

    Installing and Removing a Hard Drive .................15 Installing a Hard Drive ....................16 Removing a Hard Drive ....................18 ® Installing an Intel Z-U130 Value Solid State Drive .............20 Installing and Removing the PCI Riser Assembly ...............21 Removing the PCI Riser Assembly ................21 ®...
  • Page 8 Recovering the BIOS ......................62 Clearing the Password ......................64 Performing an iBMC Force Update ..................66 Using the iBMC Boot Block Write Protect Jumper (J1A4) ........... 68 Appendix A: Technical Reference ................71 ® viii Intel Server System SR1520ML User’s Guide...
  • Page 9 Bootable CD-ROM Disk Is Not Detected ..............97 Appendix D: Getting Help ..................99 World Wide Web ........................99 Telephone ..........................99 Appendix E: Warranty .................... 103 Limited Warranty for Intel® Chassis Subassembly Products ..........103 Appendix F: Safety Information ................107 ® Intel Server System SR1520ML User’s Guide...
  • Page 10 Seleccién de la ubicación ..................124 Manipulacién del equipo ................... 125 Advertencias de alimentacién y eléctricas ..............125 Advertencias sobre el cable de alimentación ............125 Advertencias el acceso al sistema ................126 ® Intel Server System SR1520ML User’s Guide...
  • Page 11 FCC Verification Statement (USA) ................136 Industry Canada (ICES-003) ..................137 Europe (CE Declaration of Conformity) ..............137 VCCI (Japan) ......................137 BSMI (Taiwan) ......................137 Korean Compliance (RRL) ..................138 Regulated Specified Components ................138 Product Ecology Requirements ..................139 End-of-Life/Product Recycling ..................140 ® Intel Server System SR1520ML User’s Guide...
  • Page 12 ® Intel Server System SR1520ML User’s Guide...
  • Page 13: List Of Tables

    Table 4. Setup Menu Key Use ....................60 Table 5. Power Supply Output Capability ................74 Table 6. System Environmental Specifications ...............75 Table 7. Resetting the System ....................89 Table 8. Product Regulatory Compliance Markings ..............133 ® Intel Server System SR1520ML User’s Guide xiii...
  • Page 14 ® Intel Server System SR1520ML User’s Guide...
  • Page 15 List of Figures ® Figure 1. Intel Server System SR1520ML................1 Figure 2. Front Controls and LEDs.................... 5 Figure 3. Back Panel Connectors....................6 Figure 4. Optional Peripherals....................7 Figure 5. System Components....................8 Figure 6. Server Board Connector Locations ................9 Figure 7.
  • Page 16 Figure 49. MiBMC Force Update Jumper in the Write Enable Position ........67 Figure 50. iBMC Boot Block Write Protect Jumper (J1A4) ............. 68 Figure 51. Power Cable Routing..................... 72 Figure 52. Data Cable Routing ....................73 ® Intel Server System SR1520ML User’s Guide...
  • Page 17: Preface

    Preface About this Manual ® Thank you for purchasing and using the Intel Server System SR1520ML. This manual is written for system technicians who are responsible for troubleshooting, upgrading, and repairing this server system. This document provides reference information, feature information, and step by step instructions on how to add and replace components on the server system.
  • Page 18: Product Contents

    Product Contents ® Your Intel Server System SR1520ML ships with the following items. ® • Two Intel Server Boards X38ML installed in the server chassis • One 600-watt power supply module, installed in the server chassis • One power cable to connect to AC power (North America only) •...
  • Page 19: Server System References

    In the product box install it Accessories or other Intel Spares and Configuration Guide server products Available from your Intel field representative or on the Server Configurator Tool at http://indigo.intel.com/serverconfiguratortool/ default.aspx Hardware (peripheral Tested Hardware and Operating Systems List boards, adapter cards) At http://support.intel.com/support/motherboards/server/X38ML/...
  • Page 20 Use this Document or Software Software ® For software to manage Intel System Management Software Software 2.0 ® your Intel server At http://support.intel.com/support/motherboards/server/X38ML/ To make sure your Search for the phrase “Power Budget Tool” system falls within the At http://support.intel.com/support/motherboards/server/X38ML/...
  • Page 21: Chapter 1: Server System Features

    ® ® The Intel Server System SR1520ML ships with two Intel Server Boards X38ML installed in it. Each server board operates as a fully functioning server system with it’s own control panel, BIOS setup configuration, processor, memory, drives, add-in card, keyboard/mouse, and video monitor.
  • Page 22: Table 2. Feature Summary

    Server board Intel Server Board X38ML. Two per system. Processors Processor and Front Side Bus (FSB) support • The system supports one processor on each server board. For supported Intel processors, see http://support.intel.com/ support/motherboards/server/X38ML • Supports 800/1066/1333 MHz FSB • Memory...
  • Page 23: External Component Identification

    Each server board has one internal USB header, which supports two USB ports ® System management Intel System Management 2.0 Software External Component Identification This section helps you identify the components of your server system. If you are near the system, you can also use the quick reference label on the inside of the chassis cover to assist in identifying components.
  • Page 24 Green LED for system power supply status LED State Power State Green On DC Power is ready to be applied to the board Green Blink Board is in sleep state S1 DC Power supply is in the ‘Off’ state ® Intel Server System SR1520ML User’s Guide...
  • Page 25: Figure 2. Front Controls And Leds

    Green LED that indicates hard drive activity LED State Drive State Green blink Drive is active Drive is not active System reset button Press to reset the system Figure 2. Front Controls and LEDs ® Intel Server System SR1520ML User’s Guide...
  • Page 26: System Rear

    No network connection Solid amber Network connection in place Blinking amber Transmit/receive activity Right 10 Mbps connection (if left LED is on or blinking) Solid amber 100 Mbps connection Solid green 1000 Mbps connection ® Intel Server System SR1520ML User’s Guide...
  • Page 27: Peripheral Devices

    ® ® titled Intel Z-U130 Value Solid State Drive Mounting Kit Installation Guide for Intel Server Systems. Note: Drives can consume up to 17 watts of power each. Drives must be specified to run at a maximum ambient temperature of 45 ®...
  • Page 28: Internal Components

    Front control panel (two) PCI add-in card bracket (two) System blower fans (two) Figure 5. System Components Server Board Connectors ® The two Intel Server Boards X38ML have the same connectors / components. ® Intel Server System SR1520ML User’s Guide...
  • Page 29: Figure 6. Server Board Connector Locations

    SATA port 3 POST LEDs DIMM socket A1 W. USB header for USB 2 and 3 PCI Express* x16 riser slot DIMM socket A2 Chassis intrusion header Figure 6. Server Board Connector Locations ® Intel Server System SR1520ML User’s Guide...
  • Page 30: Configuration Jumpers

    Configuration Jumpers ® The two Intel Server Boards X38ML have the same jumpers. Callout Location Jumper Name Jumper Purpose J1A4 iBMC Boot When pins 2-3 are jumpered, the iBMC boot block Block Write is write enabled. When pins 1-2 are jumpered, the Protect iBMC boot block is write protected.
  • Page 31: Sata Raid Support

    Server System SR1520ML provides SATA (3.0 Gb/s) support.The embedded ® SATA controller embedded supports both 1.5 and 3.0 Gbps data transfer rates. The Intel RAID Technology solution, available with the ICH9R, offers data striping for higher performance (RAID Level 0) and mirroring for higher reliability (RAID Level 1).
  • Page 32: Processor

    Processor Each server board must have one processor installed. Each board can use a different processor. For a list of supported processors, see http://support.intel/com/support/ motherboards/server/X38ML. Memory Each server supports four DDR2 667 / 800 MHz unbuffered ECC DIMMs. The maximum memory capacity is 2 GB unbuffered, 1 Gbit DDR2 memory.
  • Page 33: Chapter 2: Hardware Installations And Upgrades

    Hardware Installations and Upgrades ® Caution: No components in the Intel Server System SR1520ML are hot swappable. Before removing or installing any component in this server system, you must first take the server out of service, turn off all peripheral devices connected to the system, turn off the system by pressing the power button(s), and unplug the AC power cord from the system or wall outlet.
  • Page 34: Removing And Installing The Server Cover

    6. Push rearward on the top cover to slide the cover about 3/4 inch, until it stops, then lift up on the cover to remove it. See letter “C”. AF002500 Figure 8. Removing the Server System Cover ® Intel Server System SR1520ML User’s Guide...
  • Page 35: Installing The Server System Cover

    AC power cord from the system or wall outlet. One SATA drive can be installed for each server board (two drives total). Both drive bays are at the right side of the chassis. ® Intel Server System SR1520ML User’s Guide...
  • Page 36: Installing A Hard Drive

    For easiest access to the screws on the right side of the hard drive bracket, lift the power supply from the system. 5. Lift the drive carrier from the system. See letter “B” in the figure. AF002600 Figure 10. Removing Drive Carrier from the Server System ® Intel Server System SR1520ML User’s Guide...
  • Page 37: Figure 11. Installing The Hard Drive In The Drive Carrier

    See letter “B” in the figure below. 12. If you lifted out the power supply to access the drive bracket screws, set the power supply back into place. See letter “C” in the figure below. ® Intel Server System SR1520ML User’s Guide...
  • Page 38: Removing A Hard Drive

    See letter “A” in the figure below. 5. Lift the drive carrier from the chassis. See letter “B” in the figure below. ® Intel Server System SR1520ML User’s Guide...
  • Page 39: Figure 13. Removing Drive Carrier

    10. Set the drive assembly into place in the chassis. See letter “A” in the figure below. 11. Attach the drive assembly to the chassis with the screws that you removed earlier. See letter “B” in the figure below. ® Intel Server System SR1520ML User’s Guide...
  • Page 40: Z-U130 Value Solid State Drive

    ® ® Caution: The Intel VSSD is NOT hot swappable. Before removing or replacing the Intel VSSD, you must first take the server out of service, turn off all peripheral devices connected to the system, turn off the system by pressing the power button, and unplug the AC power cord from the system or wall outlet.
  • Page 41: Installing And Removing The Pci Riser Assembly

    3. Remove the server system cover. For instructions, see “Removing the Server System Cover” on page ® 4. Follow the instructions in the document titled Intel Z-U130 Value Solid State ® Drive Mounting Kit Installation Guide for Intel Server Systems.
  • Page 42: Installing The Pci Riser Assembly

    2. Press down uniformly until the riser card is seated on the server board. 3. Insert the screw into the riser assembly bracket. See letter “B” in the figure. ® Intel Server System SR1520ML User’s Guide...
  • Page 43: Figure 16. Installing Pci Riser Assembly Into The Server System

    AF002513 Figure 16. Installing PCI Riser Assembly into the Server System 4. Install the server system cover. For instructions, see “Installing the Server System Cover”. ® Intel Server System SR1520ML User’s Guide...
  • Page 44: Removing And Installing The Pci Riser Card

    Save these screws for later. Remove the riser card from the riser assembly. AF002533 Figure 17. Removing Riser Card from Riser Assembly 8. Install the replacement riser card. For instructions, see “Installing a PCI Riser Card” on page 9. Choose the appropriate action: ® Intel Server System SR1520ML User’s Guide...
  • Page 45: Installing A Pci Riser Card

    — Install a PCI add-in card if desired. For instructions, see “Installing a PCI Add- in Card” on page — Install the PCI riser assembly into the server system. For instructions, see “Installing the PCI Riser Assembly” on page ® Intel Server System SR1520ML User’s Guide...
  • Page 46: Installing And Removing A Pci Add-In Card

    See letter “A” in the figure below. 8. Re-install the screw you removed in step 5. See letter “B” in the figure. AF002515 Figure 19. Installing an Add-In Card ® Intel Server System SR1520ML User’s Guide...
  • Page 47: Removing A Pci Add-In Card

    7. If you are not installing a replacement add-in card, install a filler panel over the opening at the rear of the riser assembly. 8. Re-install the screw you removed in step 5. AF002514 Figure 20. Removing an Add-In Card ® Intel Server System SR1520ML User’s Guide...
  • Page 48: Removing And Installing The Processor Air Duct

    3. Remove the server system cover. For instructions, see “Removing the Server System Cover”. 4. Lift the processor air duct from its location behind the two fans. See the figure below. AF002502 Figure 21. Removing the Processor Air Duct ® Intel Server System SR1520ML User’s Guide...
  • Page 49: Installing The Processor Air Duct

    Installing and Removing Memory Caution: The memory is NOT hot swappable. Before removing or replacing any memory DIMM, you must first take the server out of service, turn off all peripheral devices connected to ® Intel Server System SR1520ML User’s Guide...
  • Page 50: Memory Population Rules

    DIMMs. Memory Population Rules ® Each server board in the Intel Server System SR1520ML provides four DIMM sockets across two banks. For each server board, Bank 1 consists of DIMM sockets A1 and B1. Bank 2 consists of DIMM sockets A2 and B2. For single-channel operation, either channel may be used and DIMM sockets within the same channel can be populated in any order.
  • Page 51: Figure 23. Installing Memory Dimms

    11. Close the clips and make sure they are firmly in place. See letter “D” in the figure. 12. Install the processor air duct. For instructions, see “Installing the Processor Air Duct” on page 13. Install the server system cover. For instructions, see “Installing the Server System Cover”. ® Intel Server System SR1520ML User’s Guide...
  • Page 52: Removing Dimms

    8. Close the DIMM socket clips at each edge of the socket. See letter “C”. DIMM Socket B2 DIMM Socket B1 DIMM Socket A2 DIMM Socket A1 AF002518 Figure 24. Removing Memory DIMMs ® Intel Server System SR1520ML User’s Guide...
  • Page 53: Replacing The Processor

    7. Lift the heat sink from the processor. If it does not pull up easily, twist the heat sink again. Do not force the heat sink from the processor, which could damage it. 8. Raise the processor socket handle completely. See the following figure. ® Intel Server System SR1520ML User’s Guide...
  • Page 54: Figure 25. Opening The Processor Socket Handle

    Raise the CPU load plate. See the following figure. AF000415 Figure 26. Opening the Load Plate Caution: Do not touch the socket pins; they are very sensitive and easily damaged. 10. Lift the processor from the socket. See the following figure. ® Intel Server System SR1520ML User’s Guide...
  • Page 55: Installing The Processor

    1. Remove the processor from the packaging box and remove the protective shipping cover. 2. Orient the processor with the socket so the processor cutouts match the socket notches, then set the processor into place. See the following figure. ® Intel Server System SR1520ML User’s Guide...
  • Page 56: Installing The Heat Sink

    4. Loosely screw in the captive screws on the heat sink corners in a diagonal manner as shown by the four circled numbers in the figure below. Do no fully tighten one screw before tightening another. ® Intel Server System SR1520ML User’s Guide...
  • Page 57: Replacing The Power Supply

    1. Observe the safety and ESD precautions at the beginning of this book. See “Safety Information” on page iii. 2. Power down the server and unplug all peripheral devices and the AC power cable. ® Intel Server System SR1520ML User’s Guide...
  • Page 58: Figure 30. Disconnecting Power Cables

    — From each hard drive, disconnect the power cable. The connector to the top drive is labeled P3 and the connector to the bottom drive is labeled P4. See letters “C” and “D” in the figure. AF002580 Figure 30. Disconnecting Power Cables ® Intel Server System SR1520ML User’s Guide...
  • Page 59: Figure 31. Removing Power Supply

    12. Push the bundle of cables into place between the drive carriers and the wall of the system. 13. Insert the cable bundle into the cable harness and then close the harness over the cables. ® Intel Server System SR1520ML User’s Guide...
  • Page 60: Replacing The Fans

    AC power cord from the system or wall outlet. ® Intel Server System SR1520ML User’s Guide...
  • Page 61: Replacing A Blower Fan

    See letter “A” in the figure below. 8. Lift the fan bracket with the attached fans from the server, working it out from underneath the front panel, USB, and SATA cables. See letter “B” in the figure. ® Intel Server System SR1520ML User’s Guide...
  • Page 62: Figure 34. Removing Bracket And Fans

    AF002507 Figure 34. Removing Bracket and Fans ® Intel Server System SR1520ML User’s Guide...
  • Page 63: Figure 35. Removing Fan From Fan Bracket

    Use caution to make sure you do not pinch any cables when you connect the main power supply connectors. Make sure the fan cables will not block airflow from the memory cooling fans. ® Intel Server System SR1520ML User’s Guide...
  • Page 64: Replacing A Memory Cooling Fan

    7. Remove the two screws that attach the fan to the fan bracket. Save these screws. You will re-install them later. See letter “C”. 8. Remove the fan. See letter “D”. AF002504 Figure 36. Disconnecting Memory Cooling Fan Cable ® Intel Server System SR1520ML User’s Guide...
  • Page 65: Figure 37. Connecting Memory Cooling Fan Cable

    See letter “D” in the figure. AF002504 Figure 37. Connecting Memory Cooling Fan Cable 13. Install the processor air duct. For instructions. see “Installing the Processor Air Duct” on page ® Intel Server System SR1520ML User’s Guide...
  • Page 66: Replacing A Server Board

    10. Remove the six screws from the server board. See letter “A” and the arrows indicating the screw locations in the figure below. Lift the server board from the server system. See letter “B” in the figure. ® Intel Server System SR1520ML User’s Guide...
  • Page 67: Figure 38. Removing The Server Board

    Cover”. 14. Plug all peripheral devices and the AC power cable into the server. 15. Store the components you removed (processor, DIMMs, PCI riser assembly, server board) in anti-static bags for future use. ® Intel Server System SR1520ML User’s Guide...
  • Page 68: Installing The Server Board

    7. Attach the server board with six screws. See letter “B” and the arrows indicating the screw locations in the figure. AF002521 Figure 39. Installing the Server Board 8. Install the processor and the heat sink. For instructions, see “Installing the Processor” on page ® Intel Server System SR1520ML User’s Guide...
  • Page 69 See letter “A” in the following figure. — Front panel (letter “E”) — Sys_fan_3 (letter “D”) 11. Connect the cables at the rear of the server board. — USB_2_3 (letter “C”) — SATA_0 (letter “B”) ® Intel Server System SR1520ML User’s Guide...
  • Page 70: Replacing The Front Panel Board

    AC power cord from the system or wall outlet. ® Intel Server System SR1520ML User’s Guide...
  • Page 71 8. Disconnect the front panel cable and the USB cables from the front panel board. For ease of identification, the USB cables are two different colors. Note which color is attached to which server board. See letter “C” in the figure. ® Intel Server System SR1520ML User’s Guide...
  • Page 72: Figure 41. Removing Front Panel Board

    See letter “B” in the figure. 11. Slide the front panel board forward to match the screw holes in the board and system. Screw the front panel board into place. See letters “C” and “D” in the figure. ® Intel Server System SR1520ML User’s Guide...
  • Page 73: Replacing The Cmos Battery

    AC power cord from the system or wall outlet. ® Intel Server System SR1520ML User’s Guide...
  • Page 74 System Cover” on page 4. Remove the server's cover and locate the battery. See Figure 5. Pull back gently on the metal tab at the top of the battery. 6. Remove the battery from its socket. ® Intel Server System SR1520ML User’s Guide...
  • Page 75: Figure 43. Removing The Cmos Battery

    The “+” sign needs to face the rear of the system. 9. Install the system cover. For instructions, see “Installing the Server System Cover” on page 10. Run the BIOS Setup utility to restore the configuration settings. ® Intel Server System SR1520ML User’s Guide...
  • Page 76: Installing And Removing The Rack Handles

    “A” and “B” in the figure below. AF002527 Figure 44. Installing the Rack Handle 4. Repeat step 3 on the opposite side of the server. 5. Plug all peripheral devices and the AC power cable into the server. ® Intel Server System SR1520ML User’s Guide...
  • Page 77: Removing The Rack Handles

    “A” and “B” in the figure below. AF002526 Figure 45. Removing the Rack Handle 4. Repeat step 3 on the opposite side of the system. 5. Plug all peripheral devices and the AC power cable into the server. ® Intel Server System SR1520ML User’s Guide...
  • Page 78 ® Intel Server System SR1520ML User’s Guide...
  • Page 79: Chapter 3: Server Utilities

    These parameters can be changed if the user has adequate security rights. If a value cannot be changed for any reason, the feature's value field is inaccessible. ® Intel Server System SR1520ML User’s Guide...
  • Page 80: Table 4. Setup Menu Key Use

    If "No" is selected and the <Enter> key is pressed, or if the <Esc> key is pressed, the user is returned to where they were before <F9> was pressed without affecting any existing field values. ® Intel Server System SR1520ML User’s Guide...
  • Page 81: Upgrading The Bios

    Press <F2> Key if you want to run SETUP 2. Write down the current settings in the BIOS Setup program. Note: Do not skip step 2. You will need these settings to configure your computer at the end of the procedure. ® Intel Server System SR1520ML User’s Guide...
  • Page 82: Upgrading The Bios

    3. Move the J1A2 BIOS Recovery Mode jumper from the default operation position, covering pins 1 and 2 to the BIOS Recovery position, covering pins 2 and 3 as indicated in the following diagram. ® Intel Server System SR1520ML User’s Guide...
  • Page 83: Figure 46. Bios Recovery Mode Jumper In Recovery Position

    8. Power down the system and unplug the AC power cord. 9. Return the J1A2 BIOS Recovery Mode jumper to the default position, covering pins 1 and 2. 10. Close the server chassis. 11. Reconnect the AC power and power up the server. ® Intel Server System SR1520ML User’s Guide...
  • Page 84: Clearing The Password

    4. Reconnect the AC power and power up the system. 5. Power down the system and disconnect the AC power. 6. Return the J6B1 Password Clear jumper to the Password Clear Protect position, covering pins 1 and 2. ® Intel Server System SR1520ML User’s Guide...
  • Page 85: Figure 48. Cmos Clear Jumper In Clear Cmos Position

    AF002606 Figure 48. CMOS Clear Jumper in Clear CMOS Position 4. Reconnect the AC power, power up the system. 5. When the system begins beeping, power it down and disconnect the AC power. ® Intel Server System SR1520ML User’s Guide...
  • Page 86: Performing An Ibmc Force Update

    3. Move the J3A1 iBMC Force Update jumper from the default position, covering pins 1 and 2 to the Write Enable position, covering pins 2 and 3 as indicated in the following diagram. ® Intel Server System SR1520ML User’s Guide...
  • Page 87: Figure 49. Mibmc Force Update Jumper In The Write Enable Position

    “enabled” position. The server should never be run with the BMC force update jumper set in this position and should only be used when the standard firmware update process fails. This jumper should remain in the default, disabled position when the server is running normally. ® Intel Server System SR1520ML User’s Guide...
  • Page 88: Using The Ibmc Boot Block Write Protect Jumper (J1A4)

    Protect) Protect Write J1A4 Enable AF002607 Figure 50. iBMC Boot Block Write Protect Jumper (J1A4) 4. Close the server system and reconnect AC power and power up the server and complete the update. ® Intel Server System SR1520ML User’s Guide...
  • Page 89 If this flash area becomes corrupted, then the iBMC may be rendered useless and inoperable. For this reason jumper protection is applied to this area of the flash so a user does not mistakenly write to this boot block. ® Intel Server System SR1520ML User’s Guide...
  • Page 90 ® Intel Server System SR1520ML User’s Guide...
  • Page 91: Appendix A: Technical Reference

    Use caution to make sure no cables or wires are pinched and that the airflow from the fans is not blocked. Use the figures below to determine the correct cable routing. ® Intel Server System SR1520ML User’s Guide...
  • Page 92: Power Cable Routing

    Main power (one for each server board) Blower fan (one for each server board) Drive power. Daisy cable (one connection to power a drive for each server board) Figure 51. Power Cable Routing ® Intel Server System SR1520ML User’s Guide...
  • Page 93: Data Cable Routing

    Data Cable Routing AF002528 ® Y-USB cable. One end to Intel Z-U130 Value Solid Y-Front panel cable. One end attaches to State Drive (optoinal) and the other end to the front each server board. panel (one for each server board).
  • Page 94: 600 W Power Supply Input Voltages

    Warning: Do not exceed a combined power output of 150 Watts for the +5 V and +3.3 V outputs. Exceeding a combined 90 Watts will overload the power subsystem and may cause the power supply to overheat and malfunction. ® Intel Server System SR1520ML User’s Guide...
  • Page 95: System Environmental Specifications

    7 Bels in sound power for a typical office ambient temperature (65-75 °F). Your selection of peripherals may change the noise level. Electrostatic Tested to 15 kilovolts (kV); no component damage. discharge (ESD) ® Intel Server System SR1520ML User’s Guide...
  • Page 96 ® Intel Server System SR1520ML User’s Guide...
  • Page 97: Appendix B: Installation/Assembly Safety Instructions

    5. Provide some electrostatic discharge (ESD) protection by wearing an antistatic wrist strap attached to chassis ground of the system-any unpainted metal surface-when handling components. 6. Do not operate the system with the chassis covers removed. ® Intel Server System SR1520ML User’s Guide...
  • Page 98 • Provided with a properly grounded wall outlet. • Provided with sufficient space to access the power supply cord(s), because they serve as the product's main power disconnect. ® Intel Server System SR1520ML User’s Guide...
  • Page 99: Deutsch

    Anschlußkabel von den I/O Anschlüssen oder Ports ab. 5. Tragen Sie ein geerdetes Antistatik Gelenkband, um elektrostatische Ladungen (ESD) über blanke Metallstellen bei der Handhabung der Komponenten zu vermeiden. 6. Schalten Sie das System niemals ohne ordnungsgemäß montiertes Gehäuse ein. ® Intel Server System SR1520ML User’s Guide...
  • Page 100 Schutzhandschuhe tragen. Bei falschem Einsetzen einer neuen Batterie besteht Explosionsgefahr. Die Batterie darf nur durch denselben oder einen entsprechenden, vom Hersteller empfohlenen Batterietyp ersetzt werden. Entsorgen Sie verbrauchte Batterien den Anweisungen des Herstellers entsprechend. ® Intel Server System SR1520ML User’s Guide...
  • Page 101: Français

    Notez que le commutateur CC de mise sous tension /hors tension du panneau avant n'éteint pas l'alimentation CA du système. Pour mettre le système hors tension, vous devez débrancher chaque câble d'alimentation de sa prise. ® Intel Server System SR1520ML User’s Guide...
  • Page 102 Le microprocesseur et le dissipateur de chaleur peuvent être chauds si le système a été sous tension. Faites également attention aux broches aiguës des cartes et aux bords tranchants du capot. Nous vous recommandons l'usage de gants de protection. ® Intel Server System SR1520ML User’s Guide...
  • Page 103: Español

    No intente modificar ni usar el cable de alimentación de corriente alterna, si no corresponde exactamente con el tipo requerido. El número de cables suministrados se corresponden con el número de fuentes de alimentación de corriente alterna que tenga el producto ® Intel Server System SR1520ML User’s Guide...
  • Page 104 4. Inserte el bloqueo de seguridad en el sistema y bloquéelo para impedir que pueda accederse al mismo sin autorización. 5. Conecte todos los cables externos y los cables de alimentación CA al sistema. ® Intel Server System SR1520ML User’s Guide...
  • Page 105 • "Provisto de una toma de tierra correctamente instalada. • "Provisto de espacio suficiente como para acceder a los cables de alimentación, ya que éstos hacen de medio principal de desconexión del sistema. ® Intel Server System SR1520ML User’s Guide...
  • Page 106: Italiano

    1. Aprire e rimuovere il lucchetto dal retro del sistema qualora ve ne fosse uno installato. 2. Togliere e mettere in un posto sicuro tutte le viti delle coperture. 3. Togliere le coperture. ® Intel Server System SR1520ML User’s Guide...
  • Page 107 • "Dotata di una presa a muro correttamente installata. • "Dotata di spazio sufficiente ad accedere ai cavi di alimentazione, i quali rappresentano il mezzo principale di scollegamento del sistema. ® Intel Server System SR1520ML User’s Guide...
  • Page 108 ® Intel Server System SR1520ML User’s Guide...
  • Page 109: Appendix C: Troubleshooting

    SATA drivers. Intel provides a package called the “Platform Confidence Test” that may help with your diagnostics. See “Server System References”...
  • Page 110: Problems Following Initial System Installation

    See “Server System References” on page xix for links to the tested component lists. Hardware Diagnostic Testing This section provides a more detailed approach to identifying a hardware problem and locating its source. ® Intel Server System SR1520ML User’s Guide...
  • Page 111: Verifying Proper Operation Of Key System Lights

    • Hard disk drive activity light does not light. • USB CD-ROM drive activity light does not light. • There are problems with application software. • The bootable USB CD-ROM is not detected. ® Intel Server System SR1520ML User’s Guide...
  • Page 112: Power Light Does Not Light

    • Make sure the memory DIMMs comply with the system requirements. • Make sure the memory DIMMs have been populated according to the system requirements. ® Intel Server System SR1520ML User’s Guide...
  • Page 113: Characters Are Distorted Or Incorrect

    Are the fan power connectors properly connected to the server board? • Is the cable from the control panel board connected to the both the control panel board and to the server board? ® Intel Server System SR1520ML User’s Guide...
  • Page 114: Drive Activity Light Does Not Light

    Make sure the correct networking software is installed. • If you are directly connecting two servers (without a hub), you will need a crossover cable. • Check the network controller LEDs next to the NIC connectors. ® Intel Server System SR1520ML User’s Guide...
  • Page 115: Problems With Network

    Before installing a PCI card, you should always: • Turn off the server power by using the power button on the front of the system. • Unplug the AC power cord(s) from the server. ® Intel Server System SR1520ML User’s Guide...
  • Page 116: Problems With Newly Installed Application Software

    If you are experiencing any of the above symptoms that might indicate voltage spikes on the power line, you may want to install a surge suppressor between the power outlet and the system power cord. ® Intel Server System SR1520ML User’s Guide...
  • Page 117: Devices Are Not Recognized Under Device Manager (Microsoft* Windows* Operating System)

    Devices are not Recognized under Device Manager (Microsoft* Windows* Operating System) The Microsoft* Windows* operating systems do not include all of the drivers for the ® Intel chipsets, onboard NICs, and other components. See “Server System References” on page xix for a link to the current drivers and chipset files.
  • Page 118 ® Intel Server System SR1520ML User’s Guide...
  • Page 119: Appendix D: Getting Help

    Telephone All calls are billed per incident, levied in local currency at the applicable credit card exchange rate plus applicable taxes. (Intel reserves the right to change the pricing for telephone support at any time without notice). Before calling, fill out an Issue Report Form, available at http://support.intel.com/support/...
  • Page 120: Latin America

    Easter Island....Contact AT&T USA at 800 800 311. Once connected, dial 800 843 4481 Mainland and Juan .. Contact AT&T USA at 800 225 288. Once connected, dial 800 843 4481 ® Intel Server System SR1520ML User’s Guide...
  • Page 121 Panama..Contact AT&T USA at 00 800 001 0109. Once connected, dial 800 843 4481 Paraguay ... 001 916 377 0114 Peru ... 001 916 377 0114 Uruguay..001 916 377 0114 Venezuela... Contact AT&T USA at 0 800 2255 288. Once connected, dial 800 843 4481 ® Intel Server System SR1520ML User’s Guide...
  • Page 122 ® Intel Server System SR1520ML User’s Guide...
  • Page 123: Appendix E: Warranty

    "as is" unless specifically provided for otherwise in any software license accompanying the software. If any Product furnished by Intel which is the subject of this Limited Warranty fails during the warranty period for reasons covered by this Limited Warranty, Intel, at its option, will: •...
  • Page 124: Warranty Limitations And Exclusions

    Limitations of Liability Intel's responsibility under this, or any other warranty, implied or expressed, is limited to repair, replacement, or refund, as set forth above. These remedies are the sole and exclusive remedies for any breach of warranty.
  • Page 125: How To Obtain Warranty Service

    Telephone Support If you cannot find the information you need on Intel's World Wide Web site (http:// www.intel.com/), call your local distributor or an Intel Customer Support representative.
  • Page 126 ® Intel Server System SR1520ML User’s Guide...
  • Page 127: Appendix F: Safety Information

    To reduce the risk of bodily injury, electrical shock, fire, and equipment damage, read this document and observe all warnings and precautions in ® this guide before installing or maintaining your Intel server product. In the event of a conflict between the information in this document and information provided with the product or on the Web site for a particular product, the product documentation takes precedence.
  • Page 128: Intended Application Uses

    Conform to local occupational health and safety requirements when moving and lifting equipment. • Use mechanical assistance or other suitable assistance when moving and lifting equipment. • To reduce the weight for easier handling, remove any easily detachable components. ® Intel Server System SR1520ML User’s Guide...
  • Page 129: Power And Electrical Warnings

    Do not attempt to modify or use an AC power cord if it is not the exact type required. A separate AC cord is required for each system power supply. ® Some power supplies in Intel servers use Neutral Pole Fusing. To avoid risk of shock use caution when working with power supplies that use Neutral Pole Fusing.
  • Page 130: System Access Warnings

    To avoid risk of potential electric shock, a proper safety ground must be implemented for the rack and each piece of equipment installed in it. ® Intel Server System SR1520ML User’s Guide...
  • Page 131: Electrostatic Discharge (Esd)

    Caution: To avoid risk of radiation exposure and/or personal injury: • Do not open the enclosure of any laser peripheral or device. • Laser peripherals or devices have are not user serviceable. • Return to manufacturer for servicing. ® Intel Server System SR1520ML User’s Guide...
  • Page 132: Deutsch

    Deutsch Sicherheitshinweise für den Server ® ® Das vorliegende Dokument bezieht sich auf Intel Serverplatinen, Intel Servergehäuse (Standfuß und Rack) sowie installierte Peripheriegeräte. Es enthält Warnungen und Vorsichtsmaßnahmen zur Vermeidung von Gefahren durch Verletzung, Stromschlag, Feuer und Beschädigungen von Geräten. Lesen Sie diese Dokument daher sorgfältig, ®...
  • Page 133: Zielbenutzer Der Anwendung

    Verwenden Sie mechanische oder andere geeignete Hilfsmittel zum Transportieren oder Anheben von Geräten. • Entfernen Sie alle Komponenten, die sich leicht abnehmen lassen, um das Gewicht zu reduzieren und die Handhabung zu erleichtern. ® Intel Server System SR1520ML User’s Guide...
  • Page 134: Warnungen Zu Netzspannung Und Elektrizität

    Typ entspricht. Jedes Netzteil im System muß über ein eigenes Netzkabel angeschlossen werden. Einige Netzteile von Intel Servern verwenden Nullleitersicherungen. Vorsicht ist geboten im Umgang mit Netzteilen, welche Nullleitersicherungen verwenden, um das Risiko eines elektrischen Schlages zu vermeiden Das Netzteil in diesem Produkt enthält keine Teile, die vom Benutzer gewartet werden...
  • Page 135: Warnhinweise Für Den Systemzugang

    Gehen Sie bei der Installation von Geräten im Rack immer von unten nach oben vor, und bauen Sie das schwerste Gerät an der untersten Position im Rack ein. Ziehen Sie jeweils immer nur ein Gerät aus dem Rack heraus. ® Intel Server System SR1520ML User’s Guide...
  • Page 136: Elektrostatische Entladungen (Esd)

    Inbetriebnahme des Systems ohne Abdeckung kann zur Beschädigung von Systemkomponenten führen. So bringen Sie die Abdeckung wieder an: • Vergewissern Sie sich zunächst, daß Sie keine Werkzeuge oder Teile im Gehäuse vergessen haben. ® Intel Server System SR1520ML User’s Guide...
  • Page 137: Français

    ® d’installer ou de mettre à jour votre produit serveur Intel En cas de conflit entre les informations fournies dans ce document et celles livrées avec le produit ou publiées sur le site Web pour un produit particulier, la documentation du produit prime.
  • Page 138: Domaines D'utilisation Prévus

    Bien ventilé et à l’écart des sources de chaleur telles que la lumière directe du soleil et les radiateurs. • À l’écart des sources de vibration ou des chocs physiques. • Isolé des champs électromagnétiques importants produits par des appareils électriques. ® Intel Server System SR1520ML User’s Guide...
  • Page 139: Pratiques De Manipulation De L'équipement

    Vous devez les débrancher avant d’ouvrir le châssis, d’ajouter ou de supprimer un composant non connectable à chaud. Les alimentations de certains serveurs Intel sont munies de doubles fusibles pôle/neutre: veuillez observer les précautions d'usage afin d'éviter tout risque d'eléctrocution.
  • Page 140: Avertissements Sur Le Cordon D'alimentation

    Éteignez le système en appuyant sur le bouton d’alimentation. • Déconnectez l’alimentation secteur en débranchant tous les cordons d’alimentation secteur du système ou de la prise murale. • Déconnectez l’ensemble des câbles et lignes de télécommunication qui sont connectés au système. ® Intel Server System SR1520ML User’s Guide...
  • Page 141: Avertissements Sur Le Montage En Rack

    étiqueté comme contrôlant toute l’unité, et pas uniquement le ou les serveurs. Pour éviter tout risque d’électrocution, le rack et chaque élément de l’équipement installé dans le rack doivent être correctement reliés à la terre. ® Intel Server System SR1520ML User’s Guide...
  • Page 142: Décharges Électrostatiques (Esd)

    Vérifiez tout d’abord que vous n’avez pas oublié d’outils ou de composants détachés à l’intérieur du système. • Vérifiez que les câbles, les cartes d’extension et les autres composants sont correctement installés. • Fixez les panneaux au châssis en suivant les instructions du produit. ® Intel Server System SR1520ML User’s Guide...
  • Page 143: Périphériques Laser

    Español Información de seguridad del servidor Este documento se aplica a las tarjetas de servidor de Intel®, las carcasas de servidor de Intel® (montaje en bastidor y en pedestal) y los dispositivos periféricos. Para reducir el riesgo de daños corporales, descargas eléctricas, fuego y en el equipo, lea este documento y preste atención a todos las advertencias y precauciones de esta guía antes de instalar o...
  • Page 144: Aplicaciones Y Usos Previstos

    Provista de una toma de corriente alterna correctamente conectada a tierra. • Provista de espacio suficiente para acceder a los cables de la fuente de alimentación ya que constituyen la desconexión principal de la alimentación. ® Intel Server System SR1520ML User’s Guide...
  • Page 145: Manipulacién Del Equipo

    CA estén desenchufado antes de abrir la carcasa, agregar o extraer cualquier componente que no es de conexión en funcionamiento. Algunas fuentes de alimentación de electricidad de los servidores de Intel utilizan el polo neutral del fuselaje. Para evitar riesgos de choques electricos use precauciónes al trabajar con las fuentes de alimentación que utilizan el polo neutral de fuselaje.
  • Page 146: Advertencias El Acceso Al Sistema

    Devuélvala al fabricante para repararla. • Apague el servidor y desconecte todos los cables de alimentación antes de agregar o reemplazar cualquier componente que no es de conexión en funcionamiento. ® Intel Server System SR1520ML User’s Guide...
  • Page 147 Para que no llegue a tocar los componentes que estén calientes cuando esté realizando una instalación de conexión en funcionamiento, tenga cuidado al extraer o instalar los componentes de conexión en funcionamiento. ® Intel Server System SR1520ML User’s Guide...
  • Page 148: Advertencias Sobre El Montaje En Bastidor

    Sujételas sólo por los bordes. Una vez extraída la tarjeta de su envoltorio de protección o del servidor, colóquela con el lado de los componentes hacia arriba sobre una superficie con toma de tierra y sin carga estática. Utilice una ® Intel Server System SR1520ML User’s Guide...
  • Page 149: Otros Riesgos

    Precaución Para evitar el riesgo de la exposición a radiaciones o de daños personales: • No abra la caja de ningún periférico o dispositivo láser • Los periféricos o dispositivos láser no pueden ser reparados por el usuario • Haga que el fabricante los repare ® Intel Server System SR1520ML User’s Guide...
  • Page 150 ® Intel Server System SR1520ML User’s Guide...
  • Page 151: Appendix G: Regulatory And Compliance Information

    (or higher) and operating at the same (or higher) speed as the microprocessor used on this server board. The final configuration of your end system product may require additional EMC compliance testing. For more information, please contact your local Intel representative.
  • Page 152: Product Emc Compliance - Class A Compliance

    This server system has been tested and verified to comply with the following electromagnetic compatibility (EMC) regulations when installed in a compatible Intel® host system. For information on compatible host system(s) refer to Intel's Server Builder Web site or contact your local Intel representative.
  • Page 153: Certifications/Registrations/Declarations

    RRL Certification (Korea) • IRAM Certification (Argentina) • Ecology Declaration (International) Product Regulatory Compliance Markings ® This Intel server system product is provided with the following regulatory marks. Table 8. Product Regulatory Compliance Markings Regulatory Compliance Region Marking IRAM Mark...
  • Page 154 FCC Marking (Class A) EMC Marking (Class A) Canada C-Tick Mark Australia / New Zealand VCCI Marking (Class A) Japan BSMI Certification Taiwan Number & Class A Warning GOST R Marking Russia RRL MIC Mark Korea ® Intel Server System SR1520ML User’s Guide...
  • Page 155 This notice is required by California Code of Regulations, Title 22, Division 4.5, Chapter 33: Best Management Practices for Perchlorate Materials. This product / part includes a battery which contains Perchlorate material. Country of Origin Made in XXXX ® Intel Server System SR1520ML User’s Guide...
  • Page 156: Electromagnetic Compatibility Notices

    (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. For questions related to the EMC performance of this product, contact: Intel Corporation 5200 N.E. Elam Young Parkway Hillsboro, OR 97124-6497 1-800-628-8686 This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
  • Page 157: Industry Canada (Ices-003)

    Install and use the equipment according to the instruction manual. BSMI (Taiwan) The BSMI Certification Marking and EMC warning is located on the outside rear area of the product. ® Intel Server System SR1520ML User’s Guide...
  • Page 158: Korean Compliance (Rrl)

    Updated product information for configurations can be found on the Intel Server Builder Web site at the following URL: http://channel.intel.com/go/serverbuilder If you do not have access to Intel's Web address, please contact your local Intel representative. •...
  • Page 159: Product Ecology Requirements

    Product Ecology Requirements Intel has a system in place to restrict the use of banned substances in accordance with world wide product ecology regulatory requirements. Suppliers Declarations of Conformity to the banned substances must be obtained from all suppliers; and a Material Declaration Data Sheet (MDDS) must be produced to illustrate compliance.
  • Page 160: End-Of-Life/Product Recycling

    End-of-Life / Product Recycling Product recycling and end-of-life take-back systems and requirements vary by country. Contact the retailer or distributor of this product for information about product recycling and / or take-back. ® Intel Server System SR1520ML User’s Guide...

Table of Contents