J-Web Interface; Spanning Tree Protocols; Virtual Chassis - Juniper JUNOS OS 10.4 - RELEASE NOTES REV 5 Release Note

Hide thumbs Also See for JUNOS OS 10.4 - RELEASE NOTES REV 5:
Table of Contents

Advertisement

JUNOS OS 10.4 Release Notes
194
EX Series switches do not support IPv6 interface statistics. Therefore, all values in the
output of the
show snmp mib walk ipv6IfStatsTable
of 0.
On EX Series switches, when a firewall filter is applied on the loopback (
the switch stops generating local ARP requests for transit traffic.
The
show interfaces interface-name detail | extensive
counting of packets or bytes for the transit statistics and traffic statistics counters.
You can use the counter information displayed under the
the output.
When MVRP is configured on a trunk interface, you cannot configure connectivity fault
management (CFM) on that interface.
On EX Series switches, if you clear LAG interface statistics while the LAG is down, then
bring up the LAG and pass traffic without checking for statistics, and finally bring the
LAG interface down and check interface statistics again, the statistics might be
inaccurate. As a workaround, use the
check LAG interface statistics before bringing down the interface. [PR/542018]
If you insert Gigabit Ethernet transceivers in 40-port SFP+ line cards installed in EX8200
switches, the transceivers are incorrectly shown as copper transceivers in the image
of the switch in the Dashboard page in the J-Web interface.
When you are editing an interface-range configuration in the private mode, if you change
the end of the range of the
a workaround, edit the end of the range of the
configuration mode.

J-Web Interface

If you try to commit a candidate configuration in the CLI using the Point and Click CLI
in the J-Web interface, an error is displayed on the configuration page.

Spanning Tree Protocols

If you delete multiple spanning-tree protocol interfaces from a configuration using a
single
command and then add the interfaces back to the configuration, the
commit
spanning-tree protocol packets might be dropped. As a workaround, use a separate
command to delete each spanning-tree protocol interface.
commit

Virtual Chassis

On EX8200 Virtual Chassis systems, ECMP might not work for links present between
Virtual Chassis.
On an EX8200 Virtual Chassis with a single hard disk, the hard disk might not boot.
The error message is "TIMEOUT - WRITE_DMA retrying".
After you reboot or upgrade the software on members of an EX8200 Virtual Chassis,
the FPCs might not come up for more than eight minutes when the Virtual Chassis has
a square topology. (This is a topology in which the Routing Engines of member 0
connect to those of member 8, the Routing Engines of member 1 connect to those of
command always display a count
command might display double
show interfaces interface-name
member-range
statement, the configuration might fail. As
member-range
Copyright © 2011, Juniper Networks, Inc.
lo0
) interface,
Physical interface
section of
command to
statement in the

Advertisement

Table of Contents
loading

This manual is also suitable for:

Junos os 10.4

Table of Contents