On an interface that is receiving storm traffic, if you use the
ethernet-switching-options storm-control action-shutdown
interface, it can take up to 30 seconds for the interface to shut down. [PR/556107]
Firewall Filters
On EX4200 switches, if you configure a firewall filter with the match condition
, the error message "not supported" is displayed. [PR/543316]
tcp-established
Hardware
On EX4200 switches, the uplink port status LED on the 4-port Gigabit Ethernet SFP
does not properly indicate the status of the uplink port. [PR/528070]
If no Intraconnect module or Virtual Chassis module is installed in EX4500 switches,
the switch boots but is not fully functional. Traffic loss can occur during packet
forwarding. [PR/544628]
Infrastructure
On EX8200 switches, when IGMP snooping is enabled on an interface, the IPv6
multicast Layer 2 control frame is not forwarded to other interfaces in the same VLAN.
The result is that IPv6 and VRRP for IPv6 neighbor solicitation fails. [PR/456700]
On EX8200 switches, when you perform a graceful Routing Engine switchover (GRES)
or when you restart Ethernet switching on any spanning-tree protocol domain, a loop
might occur. [PR/516611]
On EX8200 switches, if a
action in a firewall filter configuration, logging does not work. [PR/540097]
On EX8200 switches, the LACP process (
traffic to the Routing Engine is heavy. [PR/542897]
On EX4200 switches, the SFP+ uplink module might not work correctly even though
the link status is UP. [PR/569307]
If you set a custom chassis display message with the
command, the message might remain on the LCD panel indefinitely even
message
though you did not include the
J-Web Interface
In the J-Web interface, you cannot commit some configuration changes in the Port
Configuration page and the VLAN Configuration page because of the following
limitations for port mirroring ports and port mirroring VLANs:
A port configured as the output port for an analyzer cannot be a member of any
VLAN other than the default VLAN.
A VLAN configured to receive analyzer output can be associated with only one port.
[PR/400814]
When you use the Microsoft Internet Explorer browser to open a report from the
following pages in the J-Web interface, the report opens in the same browser session:
or a
action is configured along with an
log
syslog
) might start and stop repeatedly when
lacpd
option in your command. [PR/579234]
permanent
set
command to disable the
interface
set chassis display message