Juniper JUNOS OS 10.4 - RELEASE NOTES REV 5 Release Note page 156

Hide thumbs Also See for JUNOS OS 10.4 - RELEASE NOTES REV 5:
Table of Contents

Advertisement

JUNOS OS 10.4 Release Notes
156
NOTE: Be sure to disable flow traceoptions after debugging has been
completed. Flow traceoptions might cause high CPU utilization in the
Routing Engine.
[PR/304083]
On SRX240 devices, traffic flooding occurs when multiple multicast (MC) IP group
addresses are mapped to the same MAC address because multicast switching is based
on the Layer 2 address. [PR/418519]
On SRX650 devices, the input DA errors are not updated when packets are dropped
because of MAC filtering on the following:
SRX240 device
SRX210 device
16-port and 24-port GPIMs
SRX650 front-end port
This is because of MAC filtering implemented in hardware.
[PR/423777]
On SRX5600 and SRX5800 devices, the network processing bundle configuration CLI
does not check whether PICs in the bundle are valid. [PR/429780]
On SRX650 devices, packet loss is observed when the device interoperates with an
SSG20 with AMI line encoding. [PR/430475]
On an SRX210 onboard Ethernet port, an IPv6 multicast packet received is duplicated
at the ingress. This happens only for IPv6 multicast traffic in ingress. [PR/432834]
On SRX3400 and SRX3600 devices, the ramp rate of session creation is slow at times
for fragmented UDP traffic. [PR/434508]
On SRX5800 devices, when there are nonexistent PICs in the network processing
bundle, the traffic is sent out to the PICs and is lost. [PR/434976]
The SRX5600 and SRX5800 devices create more than the expected number of flow
sessions with NAT traffic. [PR/437481]
On J Series devices, NAT traffic that goes to the WXC ISM 200 and returns clear (that
is, not accelerated by the WXC ISM 200) does not work. [PR/438152]
On SRX3400, SRX3600, SRX5600, and SRX5800 devices, there is missing information
in the
jnxJsFwAuthMultipleFailure trap
the username, IP address, application, and trap name, but the username is missing.
[PR/439314]
On SRX5800 devices, for any network processing bundle configuration change to take
effect, a reboot is needed. Currently there is no message displayed after a bundle
configuration change. [PR/441546]
message. The trap message is required to contain