Issues in Junos OS Release 10.4 for SRX Series Services Gateways and J Series Services Routers
Command-Line Interface (CLI)
On SRX650 devices, tail drops and keepalive losses are seen at high load on multilink
bundles when queue 3 (out of queue 0 to queue 7) is oversubscribed. As a workaround,
use only queue 3 for keepalive packets, and use other queues for data or voice
transmission. [PR/539353]
Dual-Stack Lite
On SRX650, SRX3400, SRX3600, SRX5600 and SRX5800 devices, if the interface
address is changed to a new address which is also the concentrator address with the
background traffic target to the address, you should manually clear the IPIP clear text
sessions with the concentrator address as the destination address, if there are any, so
that the dual-stack lite concentrator could take effect on the traffic flow. [PR/541516]
Dynamic Host Configuration Protocol (DHCP)
On SRX210 and SRX240 devices, when autoinstallation is configured to run on a
particular interface and the default static route is set with the options discard, retain,
and no-advertise, the DHCP client running on the interface tries fetching the
configuration files from the TFTP server. During this process, the UDP data port on the
TFTP server might be unreachable. Because the TFTP server is unreachable, the
autoinstallation process might remain in the configuration acquisition state. When
autoinstallation is disabled, the TFTP might fail. In this case, you should manually fetch
the file from the server or the client through the relay.
As a workaround, remove the static route discard, retain, and no-advertise options
from the configuration. [PR/454189]
Enhanced Switching
On J Series devices, if the access port is tagged with the same VLAN that is configured
at the port, the access port accepts tagged packets and determines the MAC.
[PR/302635]
Flow and Processing
On SRX Series devices, the
display aggregate session information. Instead, it displays sessions on a per-SPU basis.
[PR/264439]
On J Series devices, OSPF over a multipoint interface connected as a hub-and-spoke
network does not restart when a new path is found to the same destination.
[PR/280771]
On J Series devices, outbound filters will be applied twice for host-generated IPv4
traffic. [PR/301199]
On SRX Series devices, configuring the flow filter with the
that are not related to the configured filter. As a workaround, use the flow trace flag
with the command
basic
show security flow session
set security flow traceoptions flag
command currently does not