Interfaces - Juniper JUNOS OS 10.4 - RELEASE NOTES REV 5 Release Note

Hide thumbs Also See for JUNOS OS 10.4 - RELEASE NOTES REV 5:
Table of Contents

Advertisement

Copyright © 2011, Juniper Networks, Inc.
When the configured DNS server is not reachable, name resolution for
a long time and the output of the
appear. [PR/551739: This issue has been resolved.]
During a nonstop software upgrade (NSSU) on EX8200 switches, if the number of
routes is greater than about 100,000, the graceful Routing Engine switchover (GRES)
and nonstop active routing (NSR) synchronization might take longer than two minutes.
The result is that the NSSU timers expire and the NSSU operation aborts. [PR/559223:
This issue has been resolved.]
If a Routing Engine fails over to the backup Routing Engine, not all multicast groups
that were active on the switch recover. [PR/563030: This issue has been resolved.]
During the TFTP transfer portion of an automatic software download procedure, the
software package might be truncated or corrupted. [PR/570901: This issue has been
resolved.]
The Ethernet switching process (
change is made in CLI (either in a single commit or in separate commits):
First, you remove an interface from interface range on which VoIP is configured.
Then, you either delete the removed interface or change its address family to a family
other than
ethernet-switching
[PR/571863: This issue has been resolved.]
On an EX4200 Virtual Chassis, a
interfaces are in the held state or the connecting state. [PR/571865: This issue has
been resolved.]
On an EX4200 Virtual Chassis, a large number of
might be running. [PR/576621: This issue has been resolved.]

Interfaces

On a 40-port SFP+ line card in an EX8200 switch, if you assign different shaping rates
to different ports in a port group, you do not receive an error message when you commit
the configuration, and no error is logged in the system log. As a workaround, configure
the same shaping rate on all ports in a port group. [PR/524073: This issue has been
resolved.]
In a Q-in-Q tunneling configuration that includes aggregated Ethernet interfaces (LAGs),
after a
process restart, the member interfaces in the VLAN might be incorrectly
pfem
set. [PR/527117: This issue has been resolved.]
On EX Series switches, the configured interface hold time does not work. [PR/537477:
This issue has been resolved.]
On EX4500 switches, when you are configuring Gigabit Ethernet interfaces from the
command-line interface (CLI), automatic command completion does not work.
[PR/561565: This issue has been resolved.]
Resolved Issues in Junos OS Release 10.4 for EX Series Switches
command takes a long time to
show ntp association
) might crash and then recover when the following
eswd
.
pfem
core file might be created if all the 802.1x (
processes and defunct processes
awk
takes
localhost
dot1x
)
201

Advertisement

Table of Contents
loading

This manual is also suitable for:

Junos os 10.4

Table of Contents