JUNOS OS 10.4 Release Notes
64
When logical systems are configured, the
out and return the following error message: "error: timeout communicating with
l2-learning daemon." [PR/536604: This issue has been resolved.]
A scheduler is associated with a forwarding class, and when a forwarding class is
mapped to a different queue, the associated scheduler is not applied to the new queue.
[PR/540568: This issue has been resolved.]
In Junos OS Release 10.2, the Routing Engine-based sampling might not work if the
routing table inet.0 has a route for 128.0.0.1. The issue occurs when this route points
to an external interface. [PR/540891: This issue has been resolved.]
A GRE interface might experience an incoming packet loss if a firewall filter is configured
on the forwarding table. [PR/541901: This issue has been resolved.]
High Availability
On M120 routers, the message: "stream blocked detected message" displays when an
FEB is switched from the backup to the primary. [PR/540644: This issue has been
resolved.]
Interfaces and Chassis
The output of the
monitor interface interface-name
This issue has been resolved.]
An OAM trace displays an incorrect next-hop MAC value. [PR/494588: This issue has
been resolved.]
When traffic flows into the MPC on which a bridge-domain configuration is being
changed or the card is booting up, the forwarding software tries to access uninitialized
memory for a short duration. This is a cosmetic issue and does not have any functional
impact. [PR/506344: This issue has been resolved.]
On M7i routers with Junos OS Release 8.5 or later, the output of the
command shows the fxp0 interface to be in the link up state even when the
fxp0
interface is disabled with no cables connected. [PR/508261: This issue has been
resolved.]
When the VRRP6 master changes, there is no log output for VRRP IPv6. [PR/514821:
This issue has been resolved.]
When the PIC is configured with encapsulation atm-ccc-cell-relay psuedowires, and
the PIC throughput exceeds 152 Mbps, data loss occurs and the following error message
is displayed: "[Warning] ce_wp_poll_hspi_stats:2006: PF/Winpath SPI interface error,
rx_err_sm 243." This error message is not seen when encapsulation atm-ccc-vc-mux
is used.
As a workaround, use the atm-ccc-vc-mux encapsulation (AAL5 ATM PW), or use
atm-ccc-cell-relay and configure a larger cell bundle size. When the cell bundle size
is 5, the PIC passes 190 Mbps without error. [PR/515632: This issue has been resolved.]
When a SIB is taken offline via a CLI command, the output of the
command does not display the message "Offlined by cli command." However, this
message is correctly displayed for the FPCs. [PR/519842: This issue has been resolved.]
command might time
show bridge-domains
command is misaligned. [PR/70077:
show interfaces
show chassis sibs
Copyright © 2011, Juniper Networks, Inc.
Need help?
Do you have a question about the JUNOS OS 10.4 - RELEASE NOTES REV 5 and is the answer not in the manual?