Juniper JUNOS OS 10.4 - RELEASE NOTES REV 5 Release Note page 66

Hide thumbs Also See for JUNOS OS 10.4 - RELEASE NOTES REV 5:
Table of Contents

Advertisement

JUNOS OS 10.4 Release Notes
66
With Junos OS Release 10.2 and later, when a logical interface on an ATM-II IQ PIC is
disabled, the FPC is taken offline and brought back online, and the PIC is reenabled,
the logical interface stays down with atm_maker_check_indq error messages.
[PR/541688: This issue has been resolved.]
When a Gigabit Ethernet or an XE interface on IQ2 PICs is disabled, and the link status
is up, the traffic received from the interface might still be forwarded. [PR/543388: This
issue has been resolved.]
When neither the per-unit scheduler nor the hierarchical-scheduler is configured on a
physical interface and the physical interface has the overhead-accounting bytes
configured, it does not take effect. [PR/544608: This issue has been resolved.]
When logical interfaces are created, the NPC crashes and the FPC goes down.
[PR/545314: This issue has been resolved.]
Chassisd crashes when the
This issue has been resolved.]
When configuration changes are made that are unrelated to the interfaces, interface
sets, or PICs, a commit failure occurs with the following error message: "error: iflset
xxxx configured for nonexisting ifd ge-x/x/x." [PR/546184: This issue has been resolved.]
On a 10-Gigabit Ethernet PIC, a log is generated when the SFP is plugged in. However,
no log is generated when the SFP is not plugged in. [PR/548251: This issue has been
resolved.]
A CFM ping command fails when the maintenance domain or maintenance association
is longer than 32 characters. [PR/550014: This issue has been resolved.]
If a bridge-domain contains more than one Aggregated Ethernet, and the IRB interfaces
experiences the right sequence of MAC moves, the FPC might restart. [PR/550824:
This issue has been resolved.]
On a 10-port oversubscribed 10-Gigabit Ethernet PIC for T Series routers
(PD-5-10XGE-SFPP), the reactions configured under the
not take effect for "low-light" conditions. [PR/550851: This issue has been resolved.]
If the number of VPLS connection exceeds 31, frequent FPC and NPC crashes might
occur. [PR/552099]
The EOA family configurations over a container ATM interface might be deleted and
added again upon every commit (including unrelated commits). [PR/553077: This
issue has been resolved.]
When a remote PE's address is configured on a local loopback interface, the MVPN
PIM neighborship to that PE in a different VRF might be affected. [PR/558584]
On MX960 routers with PWR-MX960-4100-AC PEMs (high capacity AC PEMs), the
MPCs and DPCs do not power up when the system boots with only HC-AC PEM2,PEM3
being switched on, and PEM0,PEM1 being present but switched off. [PR/562125]
show chassis clocks
command is executed. [PR/545510:
Copyright © 2011, Juniper Networks, Inc.