NOTE:
The download storageArray physicalDiskFirmware command blocks all I/O
activity until a download attempt has been made for each candidate physical disk or
you issue the stop storageArray downloadPhysicalDiskFirmware command. When
the download storageArray physicalDiskFirmware command finishes downloading
the firmware image, each candidate physical disk is displayed showing the
download status for each physical disk. One of the following download status
messages is shown: Successful, Unsuccessful With Reason, or Never Attempted
With Reason.

Enable RAID Controller Module

This command revives a RAID controller module that quiesces while running
diagnostics.
Syntax
enable controller [(0 | 1)] dataTransfer
Parameters
Parameter
controller

Enable Storage Array Feature Key

This command enables a feature using a feature key file.
Syntax
enable storageArray feature file=" filename "
Description
RAID controller module that you want to
revive. Valid RAID controller module
identifiers are 0 or 1, where 0 is the RAID
controller module on the left and 1 is the
RAID controller module on the right
when viewed from the rear of the
enclosure. You must put brackets ([ ])
around the RAID controller module
identifier. If you do not specify a RAID
controller module, the storage
management software returns a syntax
error.