Set Storage Array Enclosure Positions; Set Storage Array Icmp Response - Dell PowerVault MD3000i Cli Manual

Command line interface guide
Hide thumbs Also See for PowerVault MD3000i:
Table of Contents

Advertisement

NOTE:
When using this command, you can specify one or more of the optional
parameters. You do not, however, need to use all of the parameters.

Set Storage Array Enclosure Positions

This command defines the position of the enclosures in a storage array. You
must include all enclosures in the storage array when you enter this
command.
Syntax
set storageArray enclosurePositions=( enclosure-id-
list )
Parameters
Parameter
enclosurePositions
NOTE:
This command defines the position of an enclosure in a storage array by the
position of the enclosure ID in the enclosurePositions list. For example, if you have
a RAID enclosure with an ID set to 84 and expansion enclosures with IDs set to 1
and 12, the enclosurePositions sequence (84 1 12) places the RAID enclosure in the
first position, expansion enclosure 1 in the second position, and expansion
enclosure 12 in the third position. The enclosurePositions sequence (1 84 12) places
the RAID enclosure in the second position, expansion enclosure 1 in the first
position, and expansion enclosure 12 in the third position.

Set Storage Array ICMP Response

This command returns the default values for negotiable settings for sessions
and connections, which represent the storage array's starting point for
negotiations.
Syntax
set storageArray icmpPingResponse = (TRUE | FALSE)
184
Script Commands
Description
List of enclosure IDs. The sequence of the
module IDs in the list define the positions for
the RAID enclosure and expansion enclosures in
a storage array. Valid values are 0 to 99. Separate
the enclosure ID values with a space, and put
parentheses around the list of enclosure IDs.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powervault modular disk storage manager