Dell PowerVault MD3000i Cli Manual page 152

Command line interface guide
Hide thumbs Also See for PowerVault MD3000i:
Table of Contents

Advertisement

offset= offsetValue
raidLevel=(0 | 1 | 5) segmentSize= segmentSizeValue
[owner=(0 | 1)]
Parameters
Parameter
physicalDisk or
physicalDisks
diskGroup
userLabel
capacity
offset
raidLevel
segmentSize
152
Script Commands
Description
Specifies the physical disks to assign to the virtual disk
that you want to create. Specify the enclosure ID and slot
ID for each physical disk that you assign to the virtual
disk. Enclosure ID values are 0 to 99. Slot ID values are 0
to 31. You must put brackets ([ ]) around the enclosure ID
value and the slot ID value.
Sequence number of the disk group in which to create the
new virtual disk. (To determine the sequence numbers of
the disk groups in your storage array, enter the show
storageArray profile command.)
Name to give the new virtual disk. You must put quotation
marks (" ") around the new virtual disk name.
Size of the virtual disk that you are adding to the storage
array. Size is defined in units of bytes, kilobytes,
megabytes, or gigabytes.
Number of blocks from the beginning of the disk group to
the beginning of the referenced virtual disk.
RAID level of the disk group that contains the physical
disks. Valid values are 0, 1, or 5.
Amount of data (in kilobytes) that the RAID controller
module writes on a single physical disk in a virtual disk
before writing data on the next physical disk. Valid values
are 8, 16, 32, 64, 128, 256, or 512. For information about
the segmentSize parameter, see "Using the Auto
Configure Command" on page 53.