024. BEACON TIME
Function: Sets the interval time between repeats of
the beacon message.
Available Values: OFF/1 ~ 255 sec
Default Setting: OFF

025. NUMBER STYLE

Function: Selects the Contest Number "Cut" format
for imbedded contest number.
Available Values: 1290/AUNO/AUNT/A2NO/A2NT/
12NO/12NT
Default Setting: 1290
1290: Does not abbreviate the Contest Number
AUNO: Abbreviates to "A" for "One," "U" for "Two,"
"N" for "Nine," and "O" for "Zero."
AUNT: Abbreviates to "A" for "One," "U" for "Two,"
"N" for "Nine," and "T" for "Zero."
A2NO: Abbreviates to "A" for "One," "N" for "Nine,"
and "O" for "Zero."
A2NT: Abbreviates to "A" for "One," "N" for "Nine,"
and "T" for "Zero."
12NO: Abbreviates to "N" for "Nine" and "O" for
"Zero."
12NT: Abbreviates to "N" for "Nine" and "T" for
"Zero."
026. CONTEST NUMBER
Function: Enters the initial contest number that will
increment/decrement after sending during contest
QSOs.
Available Values: 0 ~ 9999
Default Setting: 1
027. CW MEMORY 1
Function: Permits entry of the CW message for mes-
sage register 1.
Available Values: TEXT/MESSAGE
Default Setting: MESSAGE
TEXT:
You may enter the CW message from
a supplied FH-2 Remote Control Key-
pad.
MESSAGE: You may enter the CW message from
the CW keyer.
FT
9000D O
DX
PERATION
FH-2 SETUP G
M
ANUAL
ROUP
028. CW MEMORY 2
Function: Permits entry of the CW message for mes-
sage register 2.
Available Values: TEXT/MESSAGE
Default Setting: MESSAGE
TEXT:
You may enter the CW message from
a supplied FH-2 Remote Control Key-
pad.
MESSAGE: You may enter the CW message from
the CW keyer.
029. CW MEMORY 3
Function: Permits entry of the CW message for mes-
sage register 3.
Available Values: TEXT/MESSAGE
Default Setting: MESSAGE
TEXT:
You may enter the CW message from
a supplied FH-2 Remote Control Key-
pad.
MESSAGE: You may enter the CW message from
the CW keyer.
030. CW MEMORY 4
Function: Permits entry of the CW message for mes-
sage register 4.
Available Values: TEXT/MESSAGE
Default Setting: MESSAGE
TEXT:
You may enter the CW message from
a supplied FH-2 Remote Control Key-
pad.
MESSAGE: You may enter the CW message from
the CW keyer.
031. CW MEMORY 5
Function: Permits entry of the CW message for mes-
sage register 5.
Available Values: TEXT/MESSAGE
Default Setting: MESSAGE
TEXT:
You may enter the CW message from
a supplied FH-2 Remote Control Key-
pad.
MESSAGE: You may enter the CW message from
the CW keyer.