Menu Mode Setting - Yaesu FTDX9000D - DATA MANAGEMENT Operation Manual

Hide thumbs Also See for FTDX9000D - DATA MANAGEMENT:
Table of Contents

Advertisement

001. MAIN-FAST-DELAY
Function: Sets the delay time for the AGC FAST
mode of the Main band (VFO-A) receiver.
Available Values: 20 ~ 4000 msec (20 msec/step)
Default Setting: 300 msec
002. MAIN-FAST-HOLD
Function: Sets the hang time of the AGC peak volt-
age for the AGC FAST mode of the Main band (VFO-
A) receiver.
Available Values: 0 ~ 2000 msec (20 msec/step)
Default Setting: 20 msec
003.MAIN-MID-DELAY
Function: Sets the delay time for the AGC MID mode
of the Main band (VFO-A) receiver.
Available Values: 20 ~ 4000 msec (20 msec/step)
Default Setting: 700 msec
004. MAIN-MID-HOLD
Function: Sets the hang time of the AGC peak volt-
age for the AGC MID mode of the Main band (VFO-
A) receiver.
Available Values: 0 ~ 2000 msec (20 msec/step)
Default Setting: 20 msec
005. MAIN-SLOW-DELAY
Function: Sets the delay time for the AGC SLOW
mode of the Main band (VFO-A) receiver.
Available Values: 20 ~ 4000 msec (20 msec/step)
Default Setting: 2000 msec
006. MAIN-SLOW-HOLD
Function: Sets the hang time of the AGC peak volt-
age for the AGC SLOW mode of the Main band (VFO-
A) receiver.
Available Values: 0 ~ 2000 msec (20 msec/step)
Default Setting: 20 msec
FT
9000D O
DX
PERATION
AGC G
M
ANUAL
ROUP
007. SUB-FAST-DELAY
Function: Sets the delay time for the AGC FAST
mode of the Sub band (VFO-B) receiver.
Available Values: 20 ~ 4000 msec (20 msec/step)
Default Setting: 300 msec
008. SUB-FAST-HOLD
Function: Sets the hang time of the AGC peak volt-
age for the AGC FAST mode of the Sub band (VFO-
B) receiver.
Available Values: 0 ~ 2000 msec (20 msec/step)
Default Setting: 20 msec
009. SUB-MID-DELAY
Function: Sets the delay time for the AGC MID mode
of the Sub band (VFO-B) receiver.
Available Values: 20 ~ 4000 msec (20 msec/step)
Default Setting: 700 msec
010. SUB-MID-HOLD
Function: Sets the hang time of the AGC peak volt-
age for the AGC MID mode of the Sub band (VFO-
B) receiver.
Available Values: 0 ~ 2000 msec (20 msec/step)
Default Setting: 20 msec
011. SUB-SLOW-DELAY
Function: Sets the delay time for the AGC SLOW
mode of the Sub band (VFO-B) receiver.
Available Values: 20 ~ 4000 msec (20 msec/step)
Default Setting: 2000 msec
012. SUB-SLOW-HOLD
Function: Sets the hang time of the AGC peak volt-
age for the AGC SLOW mode of the Sub band (VFO-
B) receiver.
Available Values: 0 ~ 2000 msec (20 msec/step)
Default Setting: 20 msec
M
M
ENU
ODE
Page 145

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FTDX9000D - DATA MANAGEMENT and is the answer not in the manual?

Questions and answers

Table of Contents