v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v See Chapter 7, "Parts listing for IBM Flex System p24L Compute Node," on page 79 to determine which
components are CRUs and which components are FRUs.
v If an action step is preceded by Trained service technician only, that step must be performed only by a trained
service technician.
Isolation
procedure or
symbolic failing
item
Symptom
FSPSP45
The system has
detected an error
within the FSI path.
FSPSP46
Some corrupt areas
of flash or RAM
have been detected
on the service
processor.
FSPSP47
The system has
detected an error
within the PSI link.
FSPSP48
A diagnostics
function detects an
external processor
interface problem.
FSPSP49
A diagnostic function
detects an internal
processor interface
problem.
FSPSP50
A diagnostic function
detects a connection
problem between a
processor chip and a
GX chip.
440
Power Systems: IBM Flex System p24L Compute Node Installation and Service Guide
Action
Replace the system-board and chassis assembly, as described in
"Replacing the system-board and chassis assembly" on page 67.
Replace the system-board and chassis assembly, as described in
"Replacing the system-board and chassis assembly" on page 67.
Replace the system-board and chassis assembly, as described in
"Replacing the system-board and chassis assembly" on page 67.
If the failing items preceding this isolation procedure in the failing item
list do not fix the problem, contact your next level of support.
If the failing items preceding this isolation procedure in the failing item
list do not fix the problem, contact your next level of support.
If the failing items preceding this isolation procedure in the failing item
list do not fix the problem, contact your next level of support.