IBM Flex System p24L Installation And Service Manual page 165

Compute node
Hide thumbs Also See for Flex System p24L:

Advertisement

B700F120
Explanation: Informational system log entry only.
Response: No corrective action is required.
B700F130
Explanation: Thermal Power Management Device firmware error was detected.
Response: Check for server firmware updates; then, install the updates if available.
BAxxyyyy partition firmware SRCs:
The power-on self-test (POST) might display an error code that the partition firmware detects. Try to
correct the problem with the suggested action.
The BAxxyyyy SRCs below are the error codes that might be displayed if POST detects a problem. Follow
the suggested actions in the order in which they are listed until the problem is solved. If an action solves
the problem, then you can stop performing the remaining actions. See Chapter 7, "Parts listing for IBM
Flex System p24L Compute Node," on page 79 to determine which components are CRUs and which
components are FRUs.
Note: For problems persisting after completing the suggested actions, see "Checkout procedure" on page
414 and "Solving undetermined problems" on page 457.
BA000010
Explanation: The device data structure is corrupted
Response:
1. Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
BA000020
Explanation: Incompatible firmware levels were found
Response:
1. Reboot the server.
2. If the problem persists: Search RETAIN tips and the firmware change history for the reference code to determine
the recommended actions. If a firmware update is needed, see Updating the firmware
B700F120 • BA000020
Chapter 8. Troubleshooting
153