B7004715 • B7005122
B7004715
Explanation: A problem occurred when initializing, reading, or using system VPD.
Response: Replace the management card, as described in Removing the management card and Installing the
management card.
B7004750
Explanation: Informational system log entry only.
Response: No corrective action is required.
B7004788
Explanation: Informational system log entry only.
Response: No corrective action is required.
B70047CB
Explanation: Informational system log entry only.
Response: No corrective action is required.
B7005120
Explanation: System firmware detected an error
Response: If the system is not exhibiting problematic behavior, you can ignore this error. Otherwise, go to Isolating
firmware problems.
B7005121
Explanation: System firmware detected a programming problem for which a platform dump may have been
initiated.
Response:
1. Collect the event log information.
2. Collect the platform dump information.
3. Go to Isolating firmware problems.
B7005122
Explanation: An error occurred during a search for the load source.
Response: If the partition fails to startup, go to Isolating firmware problems. Otherwise, no corrective action is
required.