B200B215 • B200F005
B200B215
Explanation: A problem occurred after a partition ended abnormally.
There was a communications problem between this partition's service processor and the platform's service processor.
Response: Restart the platform.
B200C1F0
Explanation: An internal system firmware error occurred during a partition shutdown or a restart.
Response: Go to Isolating firmware problems.
B200D150
Explanation: A partition ended abnormally; there was a communications problem between this partition and the
code that handles resource allocation.
Response: Check for server firmware updates; then, install the updates if available.
B200E0AA
Explanation: A problem occurred during the power off of a partition.
Response: Go to Isolating firmware problems.
B200F001
Explanation: A problem occurred during the startup of a partition. An operation has timed out.
Response: Look for other errors and resolve them.
B200F003
Explanation: During the startup of a partition, the partition processor(s) did not start the firmware within the
time-out window.
Response: Collect the partition dump information; then, go to Isolating firmware problems.
B200F004
Explanation: Informational system log entry only.
Response: No corrective action is required.
B200F005
Explanation: Informational system log entry only.
Response: No corrective action is required.
130
Power Systems: IBM Flex System p24L Compute Node Installation and Service Guide
Need help?
Do you have a question about the Flex System p24L and is the answer not in the manual?
Questions and answers